P0745
4E20 - P0745Information saved in
GS
Fault code
4E20 - P0745
Fault text
Electronic pressure control valve 1
Fault description
Pressure Control Solenoid 'A'
Condition for fault identification
Test condition:
Registration according to control signal status,
otherwise no special conditions
Terminal condition: Ignition ON
Voltage condition:
7 ... 16V
Condition for fault memory entry
Filter counter controlled by time or events
Action in service
1. Read out error frequency counter. If fault frequency is > 2
Replace Mechatronic.
2. If fault is passive: Clear fault memory and conduct road
test under monitored conditions. If fault code is not
registered, transmission OK
If fault code is entered repeatedly Replace Mechatronic
Fault effect and breakdown warning
Driver information
Warning light:
E-gearshift: CC-ID170/173
M-gearshift: CC-ID420
Mech. emergency default mode
Service instruction
none