P1612
2DD1 - P1612Information saved in
DME
Fault code
2DD1 - P1612
Fault text
No message from instrument cluster, instrument cluster 3
Fault description
Serial Communication Link Instrument Pack
Condition for fault identification
Test condition:
1. CAN 11 vehicle (E46, E85, E83)
2. No short circuit on the PT CAN
3. INSTR3 message initialized
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
20 sec.
Action in service
Check CAN links between instrument cluster and DME
Fault effect and breakdown warning
Driver information
none
Service instruction
none