Door Lock Actuators
The CTD system uses the door lock actuators as one method to activate the alarm. The driver door module monitors all door lock actuators via a discrete input or the Simple Bus Interface (SBI) from the other three door modules. If the RIM receives a class 2 message from the driver door module that a door is open and the CTD system is armed, RIM activates the alarm.