Cylinder Lock Switch Failure/Lock
Test 1 - 3:
Test 4 - 7:
SYMPTOM
CYLINDER LOCK SWITCH FAILURE/LOCK
WHEN MONITORED
Continuously
SET CONDITION
If the CTM detects that the Cylinder Lock switch remains in the "lock" position longer then 30 seconds.
POSSIBLE CAUSES
- Driver lock switch - open
- Key cylinder mechanical malfunction
- Passenger lock switch - open
- Defective CTM - lock
- Cylinder lock switch mux circuit short to ground
- Liftgate cylinder lock switch - open