Neutral Indicator Short to Ground
SYMPTOM NEUTRAL INDICATOR SHORT TO GROUND
When Monitored and Set Condition: NEUTRAL INDICATOR SHORT TO GROUND
- When Monitored: Continuously with ignition on
- Set Condition: The Transfer Case Control Module detects a short to ground in the Neutral Indicator circuit.
POSSIBLE CAUSES
- INTERMITTENT WIRING AND CONNECTORS
- NEUTRAL INDICATOR CIRCUIT OPEN
- NEUTRAL INDICATOR CIRCUIT SHORT TO GROUND
- NEUTRAL INDICATOR CIRCUIT SHORT TO VOLTAGE
- TRANSFER CASE SELECTOR SWITCH