Bus Integrity Failure
Test 1 - 2
Symptom List:
BUS INTEGRITY FAILURE
NO COMMUNICATION WITH BCM
NO COMMUNICATION WITH EATX
NO COMMUNICATION WITH FCM
NO COMMUNICATION WITH SBEC
Test Note: All symptoms listed above are diagnosed using the same tests. The title for the tests will be BUS INTEGRITY FAILURE.
When Monitored and Set Condition:
BUS INTEGRITY FAILURE
When Monitored: When the Adjustable Pedals module is awake.
Set Condition: When the module detects no bus communication.
When Monitored and Set Condition:
NO COMMUNICATION WITH BCM
When Monitored: When the Adjustable Pedals module is awake and not doing diagnostics.
Set Condition: When the module detects no communication with the BCM.
When Monitored and Set Condition:
NO COMMUNICATION WITH EATX
When Monitored: When the Adjustable Pedals module is awake and key position is correct to receive messages.
Set Condition: When the module detects no communication with the EATX.
When Monitored and Set Condition:
NO COMMUNICATION WITH FCM
When Monitored: When the Adjustable Pedals module is awake and the key position is correct to receive messages.
Set Condition: When the module detects no communication with the FCM.
When Monitored and Set Condition:
NO COMMUNICATION WITH SBEC
When Monitored: When the Adjustable Pedals module is awake and the key position is correct to receive messages.
Set Condition: When the module detects no communication with the SBEC.
Possible Causes