Left Front Turn Signal Output Open
Tests 1 - 3:
Test 4:
SYMPTOM
LEFT FRONT TURN SIGNAL OUTPUT OPEN
WHEN MONITORED
Ignition On and left turn signal ON.
SET CONDITION
When output voltage status is LOW
POSSIBLE CAUSES
- Intermittent condition
- Ground circuit open
- Turn signal lamp open
- Left turn signal output circuit open
- Body control module