Operation CHARM: Car repair manuals for everyone.

Installation







INSTALLATION




PRESSURE DIFFERENTIAL TUBING







1. Install differential pressure tubing, if removed. Tighten fittings to 30 Nm (22 ft. lbs.).




2. Position differential pressure sensor (1).
3. Install mounting nuts (5) and bolts. Tighten to 10 Nm (89 in. lbs.).

NOTE: Make sure there is not a dip in the pressure differential hoses.

4. Install hose (2) to the rear DPF tubing.
5. Install hose (3) to the front DPF tubing.
6. Connect electrical connector (6).
7. Lower vehicle.