R6 Check Circuit 512 for Ground Short
- Key OFF.- Disconnect battery ground cable.
- Disconnect fluid level switch.
- Disconnect ignition switch.
- Disconnect antilock electronic control module.
- Check for short to ground on Pin 2 of antilock electronic control module harness connector (Circuit 512).
- Is there a ground short?
YES -- Repair ground short in Circuit 512. Reconnect all components. Go to R9.
NO -- Go to R7.