C2
C2 CHECK CIRCUIT 601 (LB/PK) VOLTAGE- Key "off."
- Install EEC IV 60-Pin Breakout Box. Ensure the correct overlay is used.
- Key "on."
- Measure the voltage between EEC IV 60-Pin Breakout Box pin 20 and ground.
- Is the voltage 18 volts or greater?
> Yes
Repair charging system for over-voltage condition.
> No
Go to Pinpoint Test C3. C3