Test D: The Courtesy Lamps Do Not Turn On With One Door Open
PINPOINT TEST D: THE COURTESY LAMPS DO NOT TURN ON WITH ONE DOOR OPENNormal Operation
When any door is opened, the ajar switch opens the circuit to the smart junction box (SJB). The SJB monitors the ajar circuits, and based on the ajar status, supplies voltage to the courtesy lamps on circuit VLN33 (GY/VT).
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Door ajar switch
- SJB