Test M: The High Beam Indicator Is Never On
PINPOINT TEST M: THE HIGH BEAM INDICATOR IS NEVER ONNormal Operation
When the high beams are turned on, the SJB routes voltage to the instrument cluster (IC) through circuit SBR14 (BN/RD) to illuminate the high beam indicator. The instrument cluster (IC) provides the bulb ground through circuit GD161 (BK/YE).
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- SJB
- Instrument cluster (IC)