Principles of Operation
PRINCIPLES OF OPERATIONNOTE: The smart junction box (SJB) is also known as the generic electronic module (GEM).
Voltage is supplied at all times to the parking lamp relay. The parking lamp relay is internal to the smart junction box (SJB). When the headlamp switch is placed in the PARKING LAMPS ON position, voltage is routed to the SJB, signaling a request for parking lamps. When the SJB receives this request voltage is supplied to the parking lamps.