Audio System Information Does Not Display On The Audio-HVAC Display Unit (Without Navigation, With Climate Control)
Audio System Symptom Troubleshooting - Audio system information does not display on the audio-HVAC display unit
Audio system information does not display on the audio-HVAC display unit (with climate control)
NOTE:
- Check the vehicle battery condition first Battery Test.
- Check the connectors for poor connections or loose terminals.
1. Turn the ignition switch to LOCK (0).
2. Remove the audio-HVAC display unit Audio-HVAC Display Unit Removal/Installation.
3. Check the connections at the audio-HVAC display unit 12P connector.
Are the connectors and terminals connected properly?
YES -
Go to step 4.
NO -
Repair the connection, and recheck.
4. Turn the ignition switch to ON (II).
5. Measure the voltage between body ground and audio-HVAC display unit 12P connector terminals No. 5 and No. 6 individually.
Is there battery voltage?
YES -
Go to step 6.
NO -
If the +B wire does not have voltage, repair an open in the wire between the under-hood fuse/relay box and audio-HVAC display unit. If the IG2 wire does not have voltage, repair an open in the wire between the under-dash fuse/relay box and the Audi-HVAC display unit.
6. Measure the voltage between audio-HVAC display unit 12P connector terminal No. 9 and body ground.
Is there less than 0.2 V?
YES -
Go to step 7.
NO -
Repair an open or high resistance in the wire between audio-HVAC display unit 12P connector terminal No. 9 and body ground (G403).
7. Turn the ignition switch to LOCK (0).
8. Disconnect audio unit connector D (20P) and the audio-HVAC display unit 12P connector.
9. Check for continuity between audio unit connector D (20P) and the audio-HVAC display unit 12P connector according to the table.
Is there continuity?
YES -
Go to step 10.
NO -
There is an open in the wire(s) between the audio unit and the audio-HVAC display unit. Replace the affected shielded harness.
10. Check for continuity between body ground and audio-HVAC display unit 12P connector according to the table.
Is there continuity?
YES -
There is a short to body ground in the wire(s) between the audio unit and the audio-HVAC display unit. Replace the affected shielded harness.
NO -
Go to step 11.
11. Check for continuity between the terminals of audio unit connector D (20P) according to the table.
Is there continuity between any of the terminals?
YES -
There is a short in the wires between the audio unit and the audio-HVAC display unit. Replace the affected shielded harness.
NO -
Substitute a known-good audio-HVAC display unit Audio-HVAC Display Unit Removal/Installation, and recheck. If the symptom/indication goes away, replace the original audio-HVAC display unit Audio-HVAC Display Unit Removal/Installation. If the symptom/indication is still present, replace the audio unit Audio Unit Removal/Installation.