Air Bypass Valve: Service and Repair
Inspection
1. Turn the ignition switch OFF.
2. Disconnect the RCV control solenoid valve connector.
3. Measure resistance between the valve terminals 1 and 2.
4. Check that the resistance is within the specification.
Specification:Refer to "Specification"
Removal
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Remove the RCV control solenoid valve after disconnect the connector (A), bolt (B) and RCV hose (C).
Installation
CAUTION:
- Do not apply oil when hose assembled.
- The hose should be inserted perfectly to nipple.
1. Installation is the reverse order of removal.
RCV Control Solenoid Valve installation bolt:
7.8 - 8.8 N.m (0.8 - 0.9 kgf.m, 5.8 - 6.5 lb-ft)