B1A64:11
-
PINPOINT TEST 24: DTCs B1A63:11 AND 15 OR DTCs B1A64:11 AND 15 - HYBRID
See the Tribute Wiring Diagram for schematic information.
Normal Operation
Under normal operation, the sunload sensor receives a ground from the HVAC module. As the light applied to the sensor changes, the PCM detects the change through the RH and LH feedback circuits.
Possible Causes
- Wiring, terminals or connectors
- Sunload sensor
- HVAC module
Diagnostic Procedure