DTC P0505 [G6]


id010295808500

DTC P0505

IAC valve circuit malfunction

DETECTION CONDITION
•  Open or short circuit is observed in idle air control system.
POSSIBLE CAUSE
•  Poor connection of connectors at IAC valve and/or PCM
•  Short to ground in wiring from IAC valve terminal A to main relay terminal D
•  Open circuit in wiring from IAC valve terminal A to main relay terminal D
•  Open circuit in wiring from IAC valve terminal B to PCM terminal 2W
•  Short to power supply circuit in wiring from IAC valve terminal B to PCM terminal 2W
•  Short to ground in wiring from IAC valve terminal B to PCM terminal 2W
•  IAC valve malfunction
•  PCM malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
VERIFY RELATED SERVICE INFORMATION AVAILABILITY
•  Check for related Service Information availability.
•  Is any related Service Information available?
Yes
Perform repair or diagnosis according to available Service Information.
•  If vehicle is not repaired, go to the next step.
No
Go to the next step.
2
VERIFY OTHER RELATED DTC IS STORED
•  Verify stored DTC.
•  Have DTCs P0100, P0340, P0443 and/or P1250 been stored?
Yes
Inspect for open circuit in following wiring harnesses, then go to Step 9.
•  Main relay terminal D and PRC solenoid valve, MAF sensor, CMP sensor, purge solenoid valve
•  Between PCM terminal 2C and engine ground
No
Go to the next step.
3
INSPECT IAC VALVE AND PCM CONNECTORS FOR POOR CONNECTION
•  Does IAC valve connector or PCM connector have poor connection?
Yes
Repair or replace connector, then go to Step 9.
No
Go to the next step.
4
INSPECT IAC VALVE POWER SUPPLY CIRCUIT FOR OPEN OR SHORT TO GROUND
•  Disconnect IAC valve connector.
•  Turn ignition switch to the ON position.
•  Is there battery positive voltage at IAC valve harness side connector terminal A?
Yes
Go to the next step.
No
Inspect for open or short circuit in wiring harness (between main relay terminal D and IAC valve terminal A), then go to Step 9.
5
INSPECT IAC VALVE CONTROL SIGNAL CIRCUIT FOR OPEN
•  Disconnect PCM connector.
•  IAC valve is disconnected.
•  Is there continuity between IAC valve harness side connector terminal B and PCM harness side connector terminal 2W?
Yes
Go to the next step.
No
Repair open circuit, then go to Step 9.
6
INSPECT IAC VALVE CONTROL SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY
•  Is there continuity from PCM harness side connector terminal 2W to 1B?
Yes
Repair short to power supply circuit, then go to Step 9.
No
Go to the next step.
7
INSPECT IAC VALVE CONTROL SIGNAL CIRCUIT FOR SHORT TO GROUND
•  Is there continuity from PCM harness side connector terminal 2W to body ground?
Yes
Repair short to ground circuit, then go to Step 9.
No
Go to the next step.
8
INSPECT IAC VALVE
•  Is resistance between IAC valve component side connector A and B as specified?
Yes
Go to the next step.
No
Replace the IAC valve, then go to the next step.
9
VERIFY TROUBLESHOOTING OF DTC P0505 COMPLETED
•  Make sure to reconnect all disconnected connectors.
•  Clear DTC from memory using M-MDS.
•  Start engine.
•  Retrieve the DTCs using the M-MDS.
•  Is same DTC present?
Yes
Replace the PCM, then go to the next step.
No
Go to the next step.
10
VERIFY AFTER REPAIR PROCEDURE
•  Perform “AFTER REPAIR PROCEDURE”.
•  Is there any DTC present?
Yes
Go to applicable DTC inspection.
No
Troubleshooting completed.