STARTER INSPECTION [WLT-1, WLT-2, WL-C, WE-C]
id011998800300
On-vehicle Inspection
1. Verify that the battery is fully charged.
2. The starter is normal if it rotates smoothly and without any noise when the engine is cranked.
No-load test
1. Verify that the battery is fully charged.
2. Connect the starter, battery, and a tester as shown in the figure.
dpe119bw1003
|
3. Operate the starter and verify that it rotates smoothly.
4. Measure the voltage and current while the starter is operating.
Magnetic Switch Operation Inspection
Pull-out test
1. Verify that the starter motor pinion is protracted while battery positive voltage is connected to terminal S and the starter body is grounded.
chu0119w023
|
Return test
1. Disconnect the motor wire from terminal M.
2. Connect battery positive voltage to terminal M and ground the starter body.
chu0119w022
|
3. Pull out the drive pinion with a screwdriver. Verify that it returns to its original position when released.
Pinion Gap Inspection
1. Pull out the drive pinion with the battery positive voltage connected to terminal S and the starter body grounded.
chu0119w023
|
2. Measure the pinion gap while the drive pinion is pulled.
dpe119bw1005
|
Starter Inner Parts Inspection
Armature
1. Verify that there is no conductivity between the commutator and the core at each segment using a tester.
chu0119w016
|
2. Verify that there is no conductivity between the commutator and the shaft using a tester.
chu0119w017
|
3. Place the armature on V-blocks, and measure the runout using a dial indicator.
chu0119w018
|
4. Measure the commutator diameter.
chu0119w019
|
5. Measure the segment groove depth of the commutator.
chu0119w020
|
Magnetic switch
1. Inspect for conductivity between terminals S and M using a tester.
chu0119w007
|
2. Inspect for conductivity between terminal S and the body using a tester.
chu0119w008
|
3. Verify that there is no conductivity between terminals M and B using a tester.
chu0119w009
|
Brush and brush holder
1. Verify that there is no conductivity between each insulated brush and plate using a tester.
chu0119w012
|
2. Measure the brush length.
chu0119w013
|
3. Measure the brush spring force using a spring balance.
chu0119w014
|