FLASHER UNIT INSPECTION


id091800851700

1.  Connect the connector to the flasher unit.

2.  Connect the negative battery cable.

3.  Measure the voltage at the flasher unit using voltmeter.

•  When inspecting terminal F for continuity, disconnect the flasher unit connector.

4.  If the value are not as specified in the Terminal Voltage List (Reference), inspect the parts under “Action” and related wiring harnesses.

5.  If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the flasher unit.


Terminal Voltage List (Reference)

abs0zw00000307

Terminal

Signal

Connected to

Test condition

Voltage (V)/

Continuity

Action

A
Power supply
HAZARD 10 A fuse
Under any condition
B+
•  Inspect HAZARD 10 A fuse
•  Inspect related harness
D
Turn signal flasher (LH)
Turn signal light (LH)
Turn signal light (LH) flashes
Alternates
1.0 or less and B+
•  Inspect turn signal light (LH)
•  Inspect related harness
Hazard warning switch at on position
Other
1.0 or less
F
Flasher unit ground
GND
Constant: inspect for continuity to ground
Yes
•  Inspect GND
G
Turn signal flasher (RH)
Turn signal light (RH)
Turn signal light (RH) flashes
Alternates
1.0 or less and B+
•  Inspect turn signal light (RH)
•  Inspect related harness
Hazard warning switch at on position
Other
1.0 or less
H
Hazard warning on
Hazard warning switch
Hazard warning switch at on position
1.0 or less
•  Inspect hazard warning switch
•  Inspect related harness
Hazard warning switch at off position
B+
I
Turn switch on/off (RH)
Combination switch
Engine switch is at ON and turn switch (RH) on
B+
•  Inspect combination switch
•  Inspect related harness
Other
1.0 or less
J
Turn switch on/off (LH)
Combination switch
Engine switch is at ON and turn switch (LH) on
B+
•  Inspect combination switch
•  Inspect related harness
Other
1.0 or less