VALVE INSPECTION [WLT-1, WLT-2, WL-3]
id011097501000
1. Measure the valve head margin thickness of each valve.
-
• If it exceeds the standard specification, replace the valve.
-
Standard valve margin thickness
-
IN: 1.5 mm {0.059 in}
EX: 0.75 mm {0.030 in}
2. Measure the length of each valve. Replace the valve if necessary.
-
• If it is less than the minimum specification, replace the valve.
-
Standard valve length
-
IN: 111.6—112.1 mm {4.394—4.413 in}
EX: 111.5—112.0 mm {4.390—4.409 in}
-
Minimum valve length
-
IN: 111.35 mm {4.384 in}
EX: 111.25 mm {4.380 in}
3. Measure the stem diameter of each valve in the X and Y directions at the three points (A, B, and C) shown in the figure.
-
• If it is less than the minimum specification, replace the valve.
-
Standard valve stem diameter
-
IN: 6.970—6.985 mm {0.2745—0.2749 in}
EX: 6.965—6.980 mm {0.2743—0.2748 in}
-
Minimum valve stem diameter
-
IN: 6.920 mm {0.2724 in}
EX: 6.915 mm {0.2722 in}