SIMULATION TEST [WL-3]
id0102b8100600
Simulation item table
Item |
Applicable component |
Unit/Condition |
Test condition |
PCM terminal |
|
---|---|---|---|---|---|
KOEO |
KOER |
||||
ACCS
|
Air conditioning compressor cycling switch
|
Off/On
|
×
|
×
|
4L
|
GOVERNOR
|
Electronic governor
|
Actuate by any duty value
(0.5—3.5 V)
|
–
|
×
|
4X, 4Y
|
EGRA
|
EGR solenoid valve (vent)
|
Actuate by any duty value
(0—100%)
|
×
|
×
|
4Q
|
EGRV
|
EGR solenoid valve (vacuum)
|
Actuate by any duty value
(0—100%)
|
×
|
×
|
4T
|
FSOV
|
Fuel cut solenoid valve
|
Off/On
|
×
|
×
|
4W
|
GP_LMP
|
Glow indicator light
|
Off/On
|
×
|
×
|
4S
|
GPC
|
Glow plug relay
|
Off/On
|
×
|
×
|
4V
|
TCV
|
Timer control valve
|
Actuate by any duty value
(0—100%)
|
×
|
×
|
4U
|