SIMULATION TEST [WL-3]


id0102b8100600

•  The simulation items are shown below.

Simulation item table

×: Applicable
—: Not applicable

Item

Applicable component

Unit/Condition

Test condition

PCM terminal

KOEO

KOER

ACCS
Air conditioning compressor cycling switch
Off/On
×
×
4L
GOVERNOR
Electronic governor
Actuate by any duty value
(0.5—3.5 V)
×
4X, 4Y
EGRA
EGR solenoid valve (vent)
Actuate by any duty value
(0—100%)
×
×
4Q
EGRV
EGR solenoid valve (vacuum)
Actuate by any duty value
(0—100%)
×
×
4T
FSOV
Fuel cut solenoid valve
Off/On
×
×
4W
GP_LMP
Glow indicator light
Off/On
×
×
4S
GPC
Glow plug relay
Off/On
×
×
4V
TCV
Timer control valve
Actuate by any duty value
(0—100%)
×
×
4U