THERMOSTAT INSPECTION [WL-C, WE-C]


id0112b6801300

Warning
•  During inspection, the thermostat and water are extremely hot and they can badly burn. Do not touch the thermostat and water directly.
Inspect the thermostat for the following and replace as necessary.
•  Open valve in room temperature
•  Opening temperature and lift of valve
Initial-opening temperature and lift of the valve
80—84 °C {176—183 °F}
Full open temperature
95 °C {203 °F}
Full open life
8.5 mm {0.33 in} or more