THERMOSTAT INSPECTION [WL-C, WE-C]
id0112b6801300
-
Warning
-
• During inspection, the thermostat and water are extremely hot and they can badly burn. Do not touch the thermostat and water directly.
Inspect the thermostat for the following and replace as necessary.
• Open valve in room temperature
• Opening temperature and lift of valve
-
Initial-opening temperature and lift of the valve
-
80—84 °C {176—183 °F}
-
Full open temperature
-
95 °C {203 °F}
-
Full open life
-
8.5 mm {0.33 in} or more