GLOW PLUG INSPECTION [WLT-1, WLT-2]


id011396804300

1.  Remove the glow plug cord. (See GLOW PLUG REMOVAL/INSTALLATION [WLT-1, WLT-2].)

2.  Measure the resistance between the glow plug terminal and the cylinder head (body ground) using an ohmmeter.

•  If not as specified, replace the glow plug. (See GLOW PLUG REMOVAL/INSTALLATION [WLT-1, WLT-2].)
absggw00000311
Glow plug resistance (Reference value)
Approx. 0.75 ohm [20°C {68°F}]