VARIABLE SWIRL CONTROL (VSC) SOLENOID VALVE INSPECTION (Australian, European (L.H.D. U.K.) specs.) [WL-C, WE-C]
id0113b6807600
-
Note
-
• Perform the following test only when directed.
1. Inspect airflow between the ports under the following conditions.
-
• If not as specified, replace the VSC solenoid valve.
• If VSC solenoid valve is nomal, perform the “Circuit Open/Short Inspection”.
Circuit Open/Short Inspection
1. Inspect for an open/short circuit in the following wiring harnesses.
-
• If there is an open/short circuit, repair or replace the wiring harnesses.
Open circuit
-
• If there is no continuity, the circuit is open. Repair or replace the wiring harness.
-
― VSC solenoid valve terminal A (wiring harness-side) and main relay terminal D
― VSC solenoid valve terminal B (wiring harness-side) and PCM terminal 181
Short circuit
-
• If there is continuity, the circuit is shorted. Repair of replace the wiring harness.
-
― VSC solenoid valve terminal A (wiring harness-side) and ground.
― VSC solenoid valve terminal B (wiring harness-side) and power supply