SEDIMENTOR SWITCH INSPECTION [WL-C, WE-C]


id0114b6806500


Continuity Inspection

Note
•  Perform the following test only when directed.

1.  Disconnect the negative battery cable.

2.  Drain fuel from the fuel filter. (See SEDIMENTOR WATER DRAINING [WL-C, WE-C].)

3.  Remove the sedimentor switch.

4.  Inspect continuity of the sedimentor switch by using an ohmmeter.

Float

Continuity

Up
Yes
Down
No

absggw00000400

5.  If not as specified, replace the sedimentor switch. If as specified, inspect following:

Open circuit
•  Ground circuit (Sedimentor switch connector terminal B and body ground)
•  Power circuit (Sedimentor switch connector terminal A and engine switch connector terminal C)
absggw00000401
absggw00000402
Short circuit
•  Ground circuit (Sedimentor switch connector terminal B and body ground to power circuit)
•  Power circuit (Sedimentor switch connector terminal A and engine switch connector terminal C to ground)

6.  Repair or replace faulty areas.

7.  Install the sedimentor switch.

8.  Reconnect the negative battery cable.

9.  Bleed air from the fuel filter.