INTAKE SHUTTER VALVE INSPECTION [WL-C, WE-C]
id0116b6811200
1. Disconnect the vacuum hose from the intake shutter valve.
2. Connect a vacuum pump to port A.
dbg116bwb706
|
3. Apply vacuum and verify that the rod moves.
Specification (WL‐C)
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Below –4 {–30, –1.2}
|
Start to move
|
Above –25.3 {–190, –7.47}
|
Fully pulled
|
Specification (WE‐C)
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Below –3.6 {–27, –1.1}
|
Start to move
|
Above –27.9 {–209, –8.24}
|
Fully pulled
|
4. Connect a vacuum pump to port A and B.
dbg116bwb707
|
5. Apply vacuum and verify that the rod moves.
Specification (WL‐C)
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Above –40 {–300, –11.8}
|
Fully pulled
|
Specification (WE‐C)
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Above –44 {–330, –13.0}
|
Fully pulled
|