BATTERY RECHARGING [WLT-1, WLT-2, WL-3, WL-C, WE-C]
id0117b3800700
-
Warning
-
• Keep all flames away from the battery, otherwise evaporated gas from the battery fluid may catch fire, and cause serious injury.
• Remove the battery filler caps when recharging to prevent battery deformation or damage.
-
Caution
-
• Do not quick charge for more than 30 min. It will damage the battery.
1. Remove the battery and then place it in a pan of water.
2. Remove the battery filler caps.
3. Connect a battery charger to the battery and adjust the charging current as follows.
-
Battery slow charge current
-
65D31R (56): 4.0—5.0 A
75D26R (52): 5.0—6.0 A
75D26L (52): 5.0—6.0 A
95D31R (64): 6.5—8.0 A
-
Battery quick charge current [30 min]
-
65D31R (56): 30 A
75D26R (52): 35 A
75D26L (52): 35 A
95D31R (64): 40 A
4. After the battery is recharged, verify that the voltage is within the specification and remains at the same value for 1 h or more after the recharging was completed.
-
• If not within the specification, replace the battery.
-
Standard voltage
-
12.4 V or more