STARTER INSPECTION [WLT-1, WLT-2, WL-3, WL-C, WE-C]


id011997800300


On-vehicle Inspection

1.  Verify that the battery is fully charged.

2.  The starter is normal if it rotates smoothly and without any noise when the engine is cranked.

•  If the starter does not operate, inspect the following:
―  Remove the starter, and inspect the starter unit.
―  Inspect the related wiring harnesses and the engine switch.


No-load test

1.  Verify that the battery is fully charged.

2.  Connect the starter, battery, and a tester as shown in the figure.

dpe119bw1003

3.  Operate the starter and verify that it rotates smoothly.

•  If the starter does not rotate smoothly, inspect the starter unit.

4.  Measure the voltage and current while the starter is operating.

•  If not within the specification, replace the starter.
Starter no load test voltage
11 V
Starter no load test current
130 A or less


Magnetic Switch Operation Inspection


Pull‐out test

Note
•  Depending on the battery charge condition, the starter motor pinion may rotate while in a protracted state. This is due to current flowing to the starter motor through the pull-in coil to turn the starter motor, and does not indicate an abnormality.

1.  Verify that the starter motor pinion is protracted while battery positive voltage is connected to terminal S and the starter body is grounded.

chu0119w023

•  If not pulled out, repair or replace the starter.


Return test

1.  Disconnect the motor wire from terminal M.

2.  Connect battery positive voltage to terminal M and ground the starter body.

chu0119w022

3.  Pull out the drive pinion with a screwdriver. Verify that it returns to its original position when released.

•  If it does not return, repair or replace the starter.


Pinion Gap Inspection

1.  Pull out the drive pinion with the battery positive voltage connected to terminal S and the starter body grounded.

chu0119w023

Caution
•  Applying power for more than 10 s can damage the starter. Do not apply power for more than 10 s.

2.  Measure the pinion gap while the drive pinion is pulled.

dpe119bw1005

•  If not as specified, adjust with an adjustment washer (between drive housing front cover and magnetic switch).
Starter pinion gap
0 mm {0 in}


Starter Inner Parts Inspection


Armature

1.  Verify that there is no conductivity between the commutator and the core at each segment using a tester.

chu0119w016

•  If there is conductivity, replace the armature.

2.  Verify that there is no conductivity between the commutator and the shaft using a tester.

chu0119w017

•  If there is conductivity, replace the armature.

3.  Place the armature on V‐blocks, and measure the runout using a dial indicator.

chu0119w018

Starter armature runout
0.1 mm {0.039 in} max.

4.  Measure the commutator diameter.

chu0119w019

•  If not within the minimum specification, replace the armature.
Starter commutator diameter
Standard: 32 mm {1.26 in}
Minimum: 31.4 mm {1.24 in}

5.  Measure the segment groove depth of the commutator.

chu0119w020

•  If not within the minimum specification, undercut the grooves to the standard depth.
Segment groove depth of starter commutator
Standard: 0.5 mm {0.020 in}
Minimum: 0.2 mm {0.008 in}


Magnetic switch

1.  Inspect for conductivity between terminals S and M using a tester.

•  If there is no conductivity, replace the magnetic switch.
chu0119w007

2.  Inspect for conductivity between terminal S and the body using a tester.

•  If there is no conductivity, replace the magnetic switch.
chu0119w008

3.  Verify that there is no conductivity between terminals M and B using a tester.

•  If there is conductivity, replace the magnetic switch.
chu0119w009


Brush and brush holder

1.  Verify that there is no conductivity between each insulated brush and plate using a tester.

•  If there is conductivity, replace the brush holder.
chu0119w012

2.  Measure the brush length.

•  If any brush is worn almost to or beyond the minimum specification, replace all the brushes.
Starter brush length
Standard: 17.5 mm {0.69 in}
Minimum: 11 mm {0.43 in}
chu0119w013

3.  Measure the brush spring force using a spring balance.

•  If not within the minimum specification, replace the brush spring.
Starter brush spring force
Standard: 26.7—36.1 N {2.73—3.68 kgf, 6.01—8.11 lbf}
Minimum: 14.7 N {1.5 kgf, 3.3 lbf}
chu0119w014