PRESSURE REGULATOR CONTROL (PRC) OPERATION [G6]


id014095201900

•  When both conditions below are satisfied, the PCM actuates the PRC solenoid valve to cut the vacuum applied to the pressure regulator for 120 s after start.
1.  ECT above 90 °C {194 °F} and IAT above 65 °C {149 °F}.
2.  Engine speed below 2,000 rpm and CTP.