INTAKE AIR TEMPERATURE (IAT) SENSOR INSPECTION [G6]
id014095802200
1. Remove the IAT sensor.
2. Heat the IAT sensor using the lamp.
absggw00000379
|
3. Measure the resistance of the IAT sensor.
Specification
Water temperature (°C {°F}) |
Resistance (kilohm) |
---|---|
20 {68}
|
28—38
|
80 {176}
|
3.1—3.9
|
absggw00000380
|
4. Reconnect the IAT sensor connector.