VARIABLE SWIRL CONTROL (VSC) OPERATION (Australian, European (L.H.D. U.K.) specs.) [WL-C, WE-C]


id0140b7106400

•  The PCM energizes the VSC solenoid valve during low engine speeds and vacuum is applied to the VSC shutter valve actuator to close the VSC shutter valve. When the VSC shutter valve closes, the intake air passage becomes narrower than normal due to the closing of one of the two intake air ports, which increases the intake airflow speed and creates a strong lateral airflow in the combustion chamber.