NO.1 NO RFW OPERATION FROM FREE TO LOCK (RFW INDICATOR LIGHT DOES NOT ILLUMINATE) [G6, WLT-1, WLT-2]
id030303801600
1
|
NO RFW OPERATION FROM FREE TO LOCK (RFW INDICATOR LIGHT DOES NOT ILLUMINATE.)
|
DESCRIPTION
|
RFW does not change from free to lock.
|
[TROUBLESHOOTING HINTS]
• Transfer neutral switch malfunction
• 4x4 indicator switch malfunction
• RFW control module malfunction
• Lock solenoid valve malfunction
• Free solenoid valve malfunction
• RFW indicator light bulb malfunction
• RFW control box malfunction
• METER*1 fuse and/or ENGINE*2 fuse malfunction
• Print plate in instrument cluster malfunction
• RFW switch malfunction
• RFW actuator malfunction
• Air leakage from vacuum hose malfunction
• One-way check valve malfunction
• Related fuses and/or harnesses malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
Disconnect RFW control module connector.
Turn ignition switch or engine switch on.
Measure voltage between RFW control module connector terminal F and ground.
Is the voltage greater than 10 V?
|
Yes
|
Go to Step 6
|
No
|
Turn ignition switch or engine switch off.
Then go to next step.
|
||
2
|
Is the METER*1, ENGINE*2 fuse OK?
|
Yes
|
Go to next step.
|
No
|
Replace METER*1, ENGINE*2 fuse.
Then go to Step 30.
|
||
3
|
Inspect RFW indicator light bulb.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Replace RFW indicator light bulb.
Then go to Step 30.
|
||
4
|
Measure voltage between instrument cluster connector terminal 1F and ground.
Is the voltage greater than 10 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between METER*1, ENGINE*2 fuse and instrument cluster.
Then go to Step 30.
|
||
5
|
Measure voltage between instrument cluster connector terminal 1D and ground.
Is the voltage greater than 10 V?
|
Yes
|
Repair wiring harness between instrument cluster and RFW control module.
Then go to Step 30
|
No
|
Repair wiring harness between main relay and free solenoid valve connector, then go to Step 30.
|
||
6
|
Measure voltage between RFW control module connector terminal H and ground.
Is the voltage greater than 10 V?
|
Yes
|
Go to Step 7.
|
No
|
Turn ignition switch or engine switch off.
Then go to next step.
|
||
7
|
Disconnect free solenoid valve connector.
Measure voltage between free solenoid valve connector terminal A and ground.
Is the voltage greater than 10 V?
|
Yes
|
Connect free solenoid valve.
Then go to next step.
|
No
|
Repair wiring harness between METER*1, ENGINE*2 fuse and RFW control module.
Then go to Step 30.
|
||
8
|
Measure voltage between free solenoid valve connector terminal B and ground.
Is the voltage greater than 10 V?
|
Yes
|
Go to next step.
|
No
|
Inspect free solenoid valve.
Then go to Step 30.
|
||
9
|
Measure voltage between RFW control module connector terminal C and ground.
Is the voltage greater than 10 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between free solenoid valve and RFW control module.
Then go to Step 30.
|
||
10
|
Disconnect lock solenoid valve connector.
Measure voltage between lock solenoid valve connector terminal A and ground.
Is the voltage greater than 10 V?
|
Yes
|
Connect lock solenoid valve.
Then go to next step.
|
No
|
Repair wiring harness between METER*1, ENGINE*2 fuse and RFW control module.
Then go to Step 30.
|
||
11
|
Measure voltage between lock solenoid valve connector terminal B and ground.
Is the voltage greater than 10 V?
|
Yes
|
Go to next step.
|
No
|
Inspect lock solenoid valve.
Then go to Step 30.
|
||
12
|
Measure voltage between RFW control module connector terminal A and ground.
Is the voltage greater than 10 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between lock solenoid valve and RFW control module.
Then go to Step 30.
|
||
13
|
Turn ignition switch or engine switch off.
Is there continuity between RFW control module connector terminal B and ground?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between RFW control module and ground.
Then go to Step 30.
|
||
14
|
Shift select lever to N position.
Is there continuity between RFW control module connector terminal L and ground?
|
Yes
|
Go to Step 18.
|
No
|
Go to next step.
|
||
15
|
Is there continuity between transfer neutral switch connector terminal A and ground?
|
Yes
|
Repair wiring harness between RFW control module and transfer neutral switch.
Then go to Step 30.
|
No
|
Go to next step.
|
||
16
|
Inspect transfer neutral switch.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Replace transfer neutral switch.
Then go to Step 30.
|
||
17
|
Is there continuity between transfer neutral switch connector terminal B and ground?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between transfer neutral switch and ground.
Then go to Step 30.
|
||
18
|
Shift select lever to 4x4 indicator position.
Is there continuity between RFW control module connector terminal K and ground?
|
Yes
|
Go to Step 22.
|
No
|
Go to next step.
|
||
19
|
Is there continuity between 4x4 indicator switch connector terminal A and ground?
|
Yes
|
Repair wiring harness between 4x4 indicator switch and RFW control module.
Then go to Step 30.
|
No
|
Go to next step.
|
||
20
|
Inspect 4x4 indicator switch.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Replace 4x4 indicator switch.
Then go to Step 30.
|
||
21
|
Is there continuity between 4x4 indicator switch connector terminal B and ground?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between 4x4 indicator switch and ground.
Then go to Step 30.
|
||
22
|
Shift select lever to 4H position.
Is there continuity between RFW control module connector terminal J and ground?
|
Yes
|
Go to Step 26.
|
No
|
Go to next step.
|
||
23
|
Is there continuity between RFW switch connector terminal A and ground?
|
Yes
|
Repair wiring harness between RFW control module and RFW switch.
Then go to Step 30.
|
No
|
Go to next step.
|
||
24
|
Inspect RFW switch.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Replace RFW switch.
Then go to Step 30.
|
||
25
|
Is there continuity between RFW switch connector terminal B and ground?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between RFW switch and ground.
Then go to Step 30.
|
||
26
|
Inspect one-way check valve.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Replace one-way check valve.
Then go to Step 30.
|
||
27
|
Inspect RFW control box.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Replace RFW control box.
Then go to Step 30.
|
||
28
|
Inspect vacuum in vacuum hoses.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Repair vacuum in vacuum hoses.
Then go to Step 30.
|
||
29
|
Inspect RFW control module.
Is it OK?
|
Yes
|
Go to next step.
|
No
|
Repair or replace RFW control module.
Then go to next step.
|
||
30
|
Turn ignition switch or engine switch on.
Shift select lever from 2H to 4H position.
Does RFW operate from free to lock?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Inspect malfunction symptoms again, then repeat from Step 1 if malfunction occurs again.
|