RFW ACTUATOR INSPECTION
id031800801300
1. Jack up the vehicle and support it on safety stands.
2. Disconnect the vacuum hoses from the actuator.
3. Connect a vacuum pump tester to the actuator (free side) as shown.
4. Apply 26.66 kPa {200 mmHg, 7.87 inHg} vacuum, and verify that the rod moves toward the left.
dbg318zwb012
|
5. Disconnect the vacuum pump tester.
6. Connect the vacuum pump tester tot he actuator (lock side) as shown.
7. Apply 26.66 kPa {200 mmHg, 7.87 inHg} vacuum, and inspect that the rod moves toward the right.
dbg318zwb013
|