RFW ACTUATOR INSPECTION


id031800801300

1.  Jack up the vehicle and support it on safety stands.

2.  Disconnect the vacuum hoses from the actuator.

3.  Connect a vacuum pump tester to the actuator (free side) as shown.

4.  Apply 26.66 kPa {200 mmHg, 7.87 inHg} vacuum, and verify that the rod moves toward the left.

dbg318zwb012

5.  Disconnect the vacuum pump tester.

6.  Connect the vacuum pump tester tot he actuator (lock side) as shown.

7.  Apply 26.66 kPa {200 mmHg, 7.87 inHg} vacuum, and inspect that the rod moves toward the right.

dbg318zwb013

•  If not correct, replace the RFW actuator.