SIMULATION FUNCTION [5R55S]


id0502c1100800

•  By using the IDS/PDS, simulation items for input/output parts preset in the TCM can be optionally selected and operated regardless of TCM control conditions.

Simulation item table

Simulation item

Applicable component

Unit

TCM terminal

PCA
Pressure control solenoid A
pis
I, CK
PCB
Pressure control solenoid B
pis
J, CK
PCC
Pressure control solenoid C
pis
M, CK
SSA
Shift solenoid A
on/off
B, CK
SSB
Shift solenoid B
on/off
C, CK
SSC
Shift solenoid C
on/off
F, CK
SSD
Shift solenoid D
on/off
D, CK
TCC
TCC control solenoid
%
A, CK