NO.1 INSUFFICIENT BLOWN AIR VOLUME AND/OR NO BLOWN AIR DEPENDING ON AIRFLOW MODE.
id070300804200
1
|
Insufficient air (or no air) blown from vents.
|
DESCRIPTION
|
• Problem with each vent and/or duct.
|
POSSIBLE CAUSE
|
• Malfunction in VENT mode system (Steps 1—4)
• Malfunction in HEAT mode system (Step 5)
• Malfunction in DEFROSTER mode system (Steps 6—8)
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
VERIFY THAT MALFUNCTION CONDITION
• When airflow mode control dial is operated, is appropriate resistance felt and can it be moved throughout its full range?
|
Yes
|
Go to next step.
|
No
|
Go to symptom troubleshooting No.3 airflow mode does not change.
|
||
2
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN VENT MODE OR OTHER SYSTEM
• Does air blow out when in VENT mode?
|
Yes
|
Go to Step 5.
|
No
|
Go to next step.
|
||
3
|
INSPECT VENT
• Is vent clogged?
|
Yes
|
Remove the obstruction, then go to Step 9.
|
No
|
Go to the next step.
|
||
4
|
VERIFY THAT DUCT IN DASHBOARD IS INSTALLED
• Is duct in dashboard properly installed?
|
Yes
|
Inspect duct for clogging, deformity and air leakage, then go to Step 9.
|
No
|
Install duct securely in the proper position, then the go to Step 9.
|
||
5
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN HEAT MODE OR DEFROSTER MODE
• Does air blow out when HEAT mode?
|
Yes
|
Go to the next step.
|
No
|
Inspect vent for clogging, then go to Step 9.
|
||
6
|
INSPECT DEFROSTER MODE
• Does air blow out when in DEFROSTER mode?
|
Yes
|
Operation is okay.
Recheck malfunction symptoms.
|
No
|
Go to the next step.
|
||
7
|
INSPECT VENT
• Is vent clogged?
|
Yes
|
Remove obstruction, then go to Step 9.
|
No
|
Go to the next step.
|
||
8
|
VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Is defroster duct properly installed?
|
Yes
|
Inspect duct for clogging, deformity, and air leakage, then go to the next step.
|
No
|
Install duct securely in the proper position, then go to the next step.
|
||
9
|
VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Does air blow out?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|