NO.5 NO TEMPERATURE CONTROL.


id070300804600

5
No temperature control
DESCRIPTION
•  Malfunction in blower unit and/or climate control unit air mix system.
POSSIBLE CAUSE
•  Malfunction in heater unit’s air mix rod, air mix link, air mix cranks, air mix shaft, air mix wire or wire clamp (Step 2, 3)
•  Bevel gear set (2) in climate control unit, air mix wire or wire clamp malfunction (Step 4)
•  Heater unit air mix door malfunction (Step 5, 6)

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT COOLANT TEMPERATURE
•  Is coolant sufficiently warmed up?
Yes
Go to the next step.
No
Warm engine up, then go to Step 7.
2
INSPECT A/C UNIT AIR MIX SYSTEM
•  Inspect heater unit’s air mix rod, air mix link, air mix cranks air mix shaft and wire clamp
―  Is there grease on air mix rod, air mix link and cranks?
―  Are air mix rod, air mix link, air mix cranks, and air mix shaft securely installed in their proper positions?
―  Is wire clamp free of deformation?
•  Are above items okay?
Yes
Go to the next step.
No
Apply grease or install air mix rod, air mix link, air mix cranks, and air mix shaft securely in their proper positions, repair wire clamp, then go to Step 7.
3
VERIFY THAT AIR MIX WIRE FROM A/C UNIT IS POSITIONED SECURELY AND CORRECTCRY
•  Is air mix wire securely installed in the correct position in relation to heater unit’s air mix link?
Yes
Go to the next step.
No
Adjust air mix wire or install securely in correct position, then go to Step 7.
4
INSPECT CLIMATE CONTROL UNIT
•  Inspect climate control unit.
―  Is bevel gear set properly engaged?
―  Is air mix wire properly installed in correct position in relation to bevel gear?
―  Is wire clamp free of deformation?
•  Are above items okay?
Yes
Go to the next step.
No
Properly engage bevel gear set or install air mix wire in correct position, repair or replace wire clamp, then go to Step 7.
5
INSPECT A/C UNIT
•  Is there any foreign material or obstruction in heater unit’s air mix doors?
Yes
Remove obstruction, then go to Step 7.
No
Go to the next step.
6
INSPECT A/C UNIT AIR MIX DOORS
•  Is heater unit’s air mix door securely and properly installed?.
Yes
Inspect door cracks or damage, the go to the next step.
No
Install door securely in proper position, then go to the next step.
7
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
•  Does unit operate in every temperature setting?
Yes
Troubleshooting completed. Explain repairs to customer.
No
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.