NO.2 NO BLOWN AIR IN AIRFLOW MODE/BLOWN AIR VOLUME DOES NOT CHANGE AT ANY FAN SPEED. [5R55S]
id070304804300
2
|
No blown air in airflow mode.Blown air volume does not change at any fan speed.
|
DESCRIPTION
|
• Malfunction in blower system.
|
POSSIBLE CAUSE
|
• Blower motor, resistor, fan switch malfunction (Step 1)
• Blower unit malfunction (Steps 2—4)
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT BLOWER SYSTEM
• Inspect the following systems and electrical parts.
• Are they okay?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace malfunctioning part, then go to Step 5.
|
||
2
|
CHECK TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE
• Turn engine switch to ON position.
• Turn fan switch on.
• Is noise coming from blower unit.
|
Yes
|
Go to the next step.
|
No
|
Go to Step 4.
|
||
3
|
INSPECT BLOWER UNIT
• Inspect fan in blower unit.
• Is fan normal?
|
Yes
|
Go to the next step.
|
No
|
Remove obstruction, repair or replace fan and blower unit case, then go to Step 5.
|
||
4
|
INSPECT BLOWER UNIT INTAKE VENT
• Is blower unit intake vent clogged?
|
Yes
|
Remove obstruction, then go to the next step.
|
No
|
Inspect if there are any obstructions in passage between blower unit and heater unit, then go to the next step.
|
||
5
|
COMFIRM THAT MALFUNCTION SYMPTOM DO NOT RECUR AFTER REPAIR
• Does air blow out?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|