BASIC POWER WINDOW SYSTEM INSPECTION [POWER WINDOW SYSTEMS (WITH AUTO-OPEN/CLOSE FUNCTION FOR DRIVER-SIDE)]
id0903j5805500
Manual Mode Function Inspection
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Turn the ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch to the ON position.
• Operate the power window using the manual open/close function on the power window main switch.
• Does the power window operate properly?
|
Yes
|
Go to the next step.
|
No
|
• Inspect the power window main switch and the wiring harness.
• Repair or replace malfunctioning part.
|
||
2
|
• Set the power cut switch to the UNLOCK position.
• Operate the power window using the power window subswitch.
• Does the power window operate properly?
|
Yes
|
Go to the next step.
|
No
|
• Inspect for the power window subswitch and the wiring harness.
• Repair or replace malfunctioning parts.
|
||
3
|
• Set the power cut switch to the LOCK position.
• Operate all power windows other than the driver side.
• Does the power window operate ?
|
Yes
|
• Inspect the power cut switch and the wiring harness.
• Replace the power window main switch.
|
No
|
• Manual mode function is normal.
• Perform the automatic mode function inspection.
|
Automatic Mode function Inspection
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Turn the ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch to the ON position.
• Operate the power window using the auto open /close function on the power window main switch.
• Does the power window operate properly?
|
Yes
|
Go to the next step.
|
No
|
If the power window automatically opens in the closing operation:
Others:
|
||
2
|
• Operate the power window main switch to the close position while the power window is in opening operation.
• Is the power window operation stopped?
|
Yes
|
Go to the next step.
|
No
|
• Replace the power window main switch. (power window control unit is malfunctioning.)
|
||
3
|
• Operate the power window main switch to open position while the power window is in closing operation.
• Is the power window operation stopped?
|
Yes
|
• Automatic mode function is normal.
• Perform the IG-OFF timer function inspection.
|
No
|
• Replace the power window main switch. (power window control unit is malfunctioning.)
|
IG-OFF Timer Function Inspection
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Close all doors.
• Turn the ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch to the ON position..
• In automatic mode, push down the power window main switch for the driver-side front door glass. The door glass should move down within approx. 43s after ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch off.
• In manual mode (finger continuously depressing the power window main switch), the door glass should move down within approx. 43s after ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch off.
• Does the driver-side front door glass move down?
|
Yes
|
• Go to the next step.
|
No
|
• If it does not move up and down upon reinspection, inspect the following:
• Repair or replace the malfunctioning part, and reinspect.
|
||
2
|
• Turn the ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch to the ON position
• In automatic mode, pull up the power window main switch for the driver-side front door glass. The door glass does not move up within approx. 43s after ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch off.
• Verify that driver-side front door glass does not operate
• Does the driver-side front door glass move up?
|
Yes
|
• If operation is not normal, replace the power window main switch, then go to the next step.
|
No
|
• Go to the next step.
|
||
3
|
• Open any doors.
• Turn the ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch to the ON position.
• Push/pull the power window main switch for the door glass within approx. 43s after ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch off.
• Verify that the door glass does not move up or down.
• Does the door glass move up or down?
|
Yes
|
• Inspect the door switch and related wiring harness.
• If above parts are normal, replace the power window main switch, then go to the next step.
• If the above parts have any malfunction, repair or replace the malfunction part, then go to the next step.
|
No
|
• Go to the next step.
|
||
4
|
• Close all doors.
• Turn the ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch to the ON position.
• Push/pull the power window main switch for door glass after approx. 60 s after ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch off.
• Verify that the door glass does not move up or down.
• Does the door glass move up or down?
|
Yes
|
• If operation is not normal, replace the power window main switch, then go to the automatic door glass return function inspection.
|
No
|
• The IG OFF timer function is normal.
• Go to the automatic door glass return function inspection.
|
Auto Reverse Pinch Protection Function Inspection
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Turn the ignition (F2, G6)/engine (WE-C, WL-3, WL-C, WLT-1, WLT-2) switch to the ON position.
• Fully open the driver"s side power window.
• Set the hammer (thickness: 10 mm or more) as shown below. Then, close the power window using auto close function.
• Inspect that the power window opens by 200 mm after contacting the hammer and stops the operation.
• Does automatic door glass return function operate properly?
|
Yes
|
• Automatic door glass return function is normal.
• Perform the two-step down function inspection.
|
No
|
Go to the next step.
|
||
2
|
• Does power window open before contacting the hammer?
|
Yes
|
|
No
|
• Initialize the power window main switch.
|
absggw00001722
|