POWER WINDOW SYSTEM OPERATION
id091200101100
Manual Open/Close
Auto-Open/Close
Auto Reverse Pinch Protection Function
IG OFF Timer
Fail-safe
Detection Condition |
Fail-safe |
Recovery Items |
|
---|---|---|---|
IG switch ON |
IG switch OFF |
||
Hall effect switch No. 1 (for jam-safe and window position detection) operation malfunction
• During up/down movement, Hall effect switch No. 2 pulse detected but Hall effect switch No. 1 pulse not detected
|
Automatic operation prohibited
|
Automatic and manual operation prohibited
|
During up movement, pulse signals for Hall effect switches No. 1 and No. 2 detected normally, and fully closed position and return/non-return ranges redetected
|
Hall effect switch No. 2 (for window movement direction detection) operation malfunction
• During up/down movement, Hall effect switch No. 1 pulse detected but Hall effect switch No. 2 pulse not detected
|
|||
Pulse signal malfunction detection (Inversion of input signals of, or large phase deviation between, Hall effect switches No. 1 and No. 2.)
• During up/down movement, difference detected between the direction detection signals from Hall effect switches No. 1 and No. 2, and the actual direction
|
|||
Non-return range downturn malfunction
• During up movement, the signal input from Hall effect switch No. 1 higher than the position stored in the P/W main switch
|
|||
Hall effect switches No. 1 and No. 2 operation malfunction
• Hall effect switches No. 1 and No. 2 pulse signal not detected after down movement initiated from the fully closed position
|