KEYLESS CONTROL MODULE INSPECTION
id091400806400
1. Remove the keyless control module without disconnecting the connector.
2. Measure the voltage at the keyless control module terminals (other than terminal L) as indicated below.
3. Disconnect the negative battery cable.
4. Disconnect the keyless control module connector and inspect for continuity between terminal L and the bracket.
5. Inspect for continuity at terminal L as indicated below.
6. If the parts and wiring harnesses are okay but the system still does not work properly, perform the troubleshooting.
Terminal Voltage Table (Reference)
absggw00001730
|
Terminal |
Signal |
Connected to |
Test condition |
Voltage (V)/Continuity |
Action |
---|---|---|---|---|---|
A
|
IG1
|
METER 15 A fuse
|
Engine switch is at ON position
|
B+
|
• Inspect METER 15 A fuse
• Inspect related harness
|
Engine switch is at LOCK or ACC position
|
Below 1.0
|
||||
B
|
Power supply
|
ROOM 15 A fuse
|
Under any condition
|
B+
|
• Inspect ROOM 15
A fuse
• Inspect related harness
|
C
|
Door open/closed
|
Door switch
|
Any door is open (any door switch is on)
|
Below 1.0
|
• Inspect door switches
• Inspect related harness
|
All door are closed (door switches are off)
|
B+
|
||||
H*1
|
Hazard
|
Flasher control module
|
Transmitter LOCK button is pressed
|
B+→Below 1.0→B+
|
• Inspect flasher control module
• Inspect related harness
|
Transmitter UNLOCK button is pressed
|
B+→Below 1.0→B+→Below 1.0→B+
|
||||
No transmitter buttons are pressed
|
B+
|
||||
J*2
|
Theft-deterrent control module
|
Theft-deterrent control module
|
Under any condition
|
5
|
• Inspect theft-deterrent control module
• Inspect related harness
|
L
|
Ground
|
GND
|
Under any condition: inspect for continuity to ground
|
Yes
|
-
|
O
|
Lock/unlock output
|
Door lock control module
|
Transmitter LOCK button is pressed
|
B+→6→B+
|
-
|
*25→2.5→5
|
• Inspect door lock control module
• Inspect related harness
|
||||
Transmitter UNLOCK button is pressed
|
B+→Below 1.0→B+
|
||||
5→Below 1.0→5*2
|
|||||
No transmitter buttons are pressed
|
B+
|
||||
5*2
|