WATER TEMPERATURE SENDER UNIT INSPECTION
id092200802500
Water temperature sender unit (WL-3)
1. Remove the water temperature sender unit. (See WATER TEMPERATURE SENDER UNIT REMOVAL [WL-3])
2. Place the sender unit in a container of water.
3. Heat the water gradually.
4. Measure and verify that the resistance between terminal of the sender unit and the sender unit body is as shown below.
Water temperature (°C {°F}) |
Resistance (ohm) |
---|---|
49.8—50.2 {121.7—122.3}
|
189.4—259.6
|
dcf922zwbo25
|
ECT sensor (WL-C, WE-C)
1. Remove the ECT sensor. (See ENGINE COOLANT TEMPERATURE (ECT) SENSOR REMOVAL/INSTALLATION [WL-C, WE-C].)
2. Place the ECT sensor in a container of water.
3. Heat the water gradually.
4. Measure and verify that the resistance between ECT sensor terminal C and the ECT sensor body is as shown below.
Water temperature (°C {°F}) |
Resistance (ohm) |
---|---|
50 {122}
|
160—230
|
dcf922zwbo26
|