Generator removal (4JJ3 with DPD)

1. Preliminary and post procedures

1. Preliminary procedures

1) Open the engine hood.

2) Disconnect the battery cable from the battery negative terminal.

Caution

  • After turning OFF the ignition switch (power mode for models with passive entry and start system), do not disconnect the battery cable within 3 minutes.
  • If the battery cable is disconnected within 3 minutes, the vehicle electronic control system may malfunction.
  • If the battery cable is disconnected, perform the setting of the front door power window switch with AUTO UP/AUTO DOWN function after connecting the battery negative terminal.

2. Engine cover removal

1) Remove the engine cover from the engine.

Legend

  1. Engine cover

3. Air duct removal

1) Remove the intake air duct from the air cleaner and radiator core support.

Legend

  1. Intake air duct
  2. Clip

2) Remove the PCV hose from the cylinder head cover and air duct.

Legend

  1. PCV hose
  2. Clamp

3) Remove the air duct from the air cleaner and turbocharger.

Legend

  1. Air duct

4. Intake hose removal

1) Remove the intake hose from the intercooler and turbocharger.

Legend

  1. Clamp
  2. Intake hose

5. Air cleaner removal

1) Disconnect the connector from the MAF and IAT sensor.

2) Remove the air cleaner from the vehicle.

Legend

  1. Air cleaner
  2. MAF and IAT sensor

6. Cooling fan belt removal

1) Loosen the tension pulley lock nut.

2) Loosen the tension pulley adjust bolt.

3) Remove the cooling fan belt from the following parts.

  • Fan pulley
  • Generator
  • Crankshaft pulley

MT models

Legend

  1. Adjust bolt
  2. Cooling fan belt
  3. Lock nut

AT models

Legend

  1. Adjust bolt
  2. Cooling fan belt
  3. Lock nut

7. A/C compressor drive belt removal

1. M/T models (Euro 5 or above)

1) Loosen the tension pulley lock nut.

2) Loosen the tension pulley adjust bolt.

3) Remove the A/C compressor drive belt from the following parts.

  • Tension pulley
  • A/C compressor
  • Crankshaft pulley
  • Idle pulley

Legend

  1. Lock nut
  2. Adjust bolt
  3. Idle pulley
  4. A/C compressor drive belt
  5. Idle pulley

2. Except M/T models (Euro 5 or above)

1) Loosen the tension pulley lock nut.

2) Loosen the tension pulley adjust bolt.

3) Remove the A/C compressor drive belt from the following parts.

  • Tension pulley
  • A/C compressor
  • Crankshaft pulley

Legend

  1. Lock nut
  2. Adjust bolt
  3. A/C compressor drive belt

8. Generator removal

1) Disconnect the B-terminal from the generator.

2) Disconnect the connector from the generator.

3) Remove the upper bracket from the generator and timing gear case.

4) Remove the generator from the lower bracket.