2) Disconnect the battery cable from the battery negative terminal.
Caution
After turning OFF the ignition switch (power mode for models with passive entry and start system), do not disconnect the battery cable within 3 minutes.
If the battery cable is disconnected within 3 minutes, the vehicle electronic control system may malfunction.
If the battery cable is disconnected, perform the setting of the front door power window switch with AUTO UP/AUTO DOWN function after connecting the battery negative terminal.
3. Blower resistor removal
1) Disconnect the connector from the blower resistor.
2) Remove the blower resistor from the blower .