ICR relay installation (RZ4E-TC)

1. Component views

ICR relay

Part name

  1. ICR relay
  2. Nut
  3. Bracket

Tightening torque

2: 8.6 N・m { 0.9 kgf・m / 76 lb・in }

2. ICR relay installation

1) Install the ICR relay to the bracket.

Tightening torque: 8.6 N・m { 0.9 kgf・m / 76 lb・in }

Legend

  1. ICR relay
  2. Bracket

2) Connect the battery cable to the B-terminal and M-terminal.

Caution

  • Do not mistake the connection position of the battery cable.

3) Connect the connector to the ICR relay.

Legend

  1. B-terminal
  2. Battery cable (Battery side)
  3. Battery cable (Starter motor side)
  4. M-terminal
  5. Connector

3. Preliminary and post procedures

1. Post procedures

1) Connect the battery cable to the battery negative terminal.

2) Referring to the following, perform the setting of the front door power window switch with AUTO UP/AUTO DOWN function.

Refer to "9.Body, Cab, Accessories 9T.Glass, Windows, Mirrors front door power window switch setting".

3) Close the engine hood.