If a malfunction is found in the auto A/C control unit power supply circuit and ground circuit, because trouble diagnosis cannot be accurately carried out, perform the control unit circuit inspection.
1) Inspect the meter fuse, and replace if the fuse is blown out.
2) If the fuse blows out again, check and repair the cause of the fuse blowout.
1) Disconnect the connector from the control panel.
2) Start the engine.
3) Measure the voltage between the control panel connector No. 4 terminal and the ground.
Specified value: Battery voltage
4) Turn OFF the ignition switch.
5) Measure the voltage between control panel connector No. 3 and the ground.
Specified value: Battery voltage