DTC DETECTION LOGIC AND CONDITIONS [SKYACTIV-D 2.2]
id0102s4100300
DTC No. |
Condition |
Detection condition |
---|---|---|
B10A2:00
|
Vehicle collision
|
• A collision signal from the SAS control module is received.
|
P0016:00
|
Camshaft position/Crankshaft position correlation problem
|
• CKP sensor and CMP sensor input signal does not match while the crankshaft rotates 15 times when the following conditions are met:
MONITORING CONDITIONS
|
P0030:00
|
A/F sensor heater control circuit range/performance problem
|
• A/F sensor heater control current is less than 0.573 A or exceeds 6.072 A on for a continuous 5 s with the following condition met.
MONITORING CONDITIONS
|
P0034:00
|
Compressor bypass solenoid valve control circuit low input
|
• If the PCM detects that the compressor bypass solenoid valve voltage at the PCM terminal 1CO is 0.19 V or less for 1 s with the following condition met, the PCM determines that the compressor bypass solenoid valve circuit voltage is low.
MONITORING CONDITIONS
|
P0035:00
|
Compressor bypass solenoid valve control circuit high input
|
• If the PCM detects that the compressor bypass solenoid valve current at the PCM terminal 1CO is 5.9 A or more for 1 s with the following condition met, the PCM determines that the compressor bypass solenoid valve circuit voltage is high.
MONITORING CONDITIONS
|
P0047:00
|
Regulating solenoid valve control circuit low input
|
• If the PCM detects that the regulating solenoid valve voltage at the PCM terminal 1CP is 0.19 V or less for 1 s with the following condition met, the PCM determines that the regulating solenoid valve circuit voltage is low.
MONITORING CONDITIONS
|
P0048:00
|
Regulating solenoid valve control circuit high input
|
• If the PCM detects that the regulating solenoid valve current at the PCM terminal 1CP is 5.9 A or more for 1 s with the following condition met, the PCM determines that the regulating solenoid valve circuit voltage is high.
MONITORING CONDITIONS
|
P004C:00
|
Wastegate solenoid valve control circuit low input
|
• If the PCM detects that the wastegate solenoid valve voltage at the PCM terminal 1CL is 0.19 V or less for 1 s with the following condition met, the PCM determines that the wastegate solenoid valve circuit voltage is low.
MONITORING CONDITIONS
|
P004D:00
|
Wastegate solenoid valve control circuit high input
|
• If the PCM detects that the wastegate solenoid valve current at the PCM terminal 1CL is 3.5 A or more for 1 s with the following condition met, the PCM determines that the wastegate solenoid valve circuit voltage is high.
MONITORING CONDITIONS
|
P0072:00*1
|
Ambient temperature sensor circuit low input
|
• The PCM monitors the input signal from the ambient temperature sensor. If the voltage from the ambient temperature sensor is below 0.2 V for 5 s, the PCM determines that the ambient temperature sensor circuit has a malfunction.
|
P0073:00*1
|
Ambient temperature sensor circuit high input
|
• The PCM monitors the input signal from the ambient temperature sensor. If the voltage from the ambient temperature sensor is above 4.8 V for 5 s, the PCM determines that the ambient temperature sensor circuit has a malfunction.
|
P0079:00
|
OCV circuit low input
|
• If the PCM detects that the OCV voltage at the PCM terminal 1CK is 0.19 V or less for 1 s with the following condition met, the PCM determines that the OCV circuit voltage is low.
MONITORING CONDITIONS
|
P007B:00
|
Boost air temperature sensor circuit range/performance problem
|
• The difference between the intake air temperature measured by IAT sensor No.1 and boost air temperature sensor exceeds 50 °C {90 °F}.
• The difference between the intake air temperature measured by IAT sensor No.2 and boost air temperature sensor exceeds 50 °C {90 °F}.
|
P007C:00
|
Boost air temperature sensor circuit low input
|
• If the PCM detects that the boost air temperature sensor voltage at the PCM terminal 1CM is 0.10 V or less for 1 s with the following condition met, the PCM determines that the boost air temperature sensor circuit voltage is low.
MONITORING CONDITIONS
|
P007D:00
|
Boost air temperature sensor circuit high input
|
• The PCM monitors the input signal from the boost air temperature sensor. If the voltage from the boost air temperature sensor is above 4.90 V for 1 s, the PCM determines that the boost air temperature sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0080:00
|
OCV control circuit high input
|
• If the PCM detects that the OCV current at the PCM terminal 1CK is 5.9 A or more for 1 s with the following condition met, the PCM determines that the OCV circuit voltage is high.
MONITORING CONDITIONS
|
P0087:00
|
Low pressure malfunction in common rail fuel pressure control system
|
• After 6 s have elapsed from the following conditions being met, the actual fuel pressure is lower than the target fuel pressure for a continuous specified period of time:
MONITORING CONDITIONS
|
P0088:00
|
High pressure malfunction in common rail fuel pressure control system
|
• After 6 s have elapsed from the following conditions being met, the actual fuel pressure is higher than the target fuel pressure for a continuous specified period of time:
MONITORING CONDITIONS
|
P0089:00
|
High pressure malfunction in common rail fuel pressure control system
|
• When the following conditions are met, the actual fuel pressure exceeds 217 Mpa {2,213 kgf/cm2, 31,473 psi} for a continuous 3 s:
MONITORING CONDITIONS
|
P0093:00
|
Fuel leakage from fuel pressure control system
|
• When the following conditions are met, the PCM detects the amount of fuel leakage as exceeding 30 mm3/stroke3 times:
MONITORING CONDITIONS
|
P0096:00
|
IAT sensor No.2 circuit range/performance problem
|
• The difference between the intake air temperature measured by IAT sensor No.1 and IAT sensor No.2 exceeds 50 °C {90 °F}.
• The difference between the intake air temperature measured by IAT sensors No.2 and boost air temperature sensor exceeds 50 °C {90 °F}.
|
P0097:00
|
IAT sensor No.2 circuit low input
|
• If the PCM detects that the IAT sensor No.2 voltage at the PCM terminal 2N is 0.10 V or less for 1 s with the following condition met, the PCM determines that the IAT sensor No.2 circuit voltage is low.
MONITORING CONDITIONS
|
P0098:00
|
IAT sensor No.2 circuit high input
|
• The PCM monitors the input signal from the IAT sensor No.2. If the voltage from the IAT sensor No.2 is above 4.90 V for 1 s, the PCM determines that the IAT sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P009B:00
|
Fuel pressure relief valve signal circuit problem
|
• The operation amount of the fuel pressure relief valve is the specified value or more when the following conditions are met:
MONITORING CONDITIONS
|
P009F:00
|
Fuel pressure relief valve malfunction (stuck close)
|
• When the following condition is met, the pressure reduction amount during the fuel pressure relief valve operation is insufficient for several seconds continuously:
MONITORING CONDITIONS
|
P0101:00
|
MAF sensor circuit range/performance problem
|
• When the following conditions are met, the intake air amount is the specification or less (fluctuates with engine speed) for a continuous 7 s.
MONITORING CONDITIONS
• When the following conditions are met, the intake air amount is the specification or more (fluctuates with engine speed) for a continuous 7 s.
MONITORING CONDITIONS
|
P0102:00
|
MAF sensor circuit low input
|
• If the PCM detects that the MAF sensor voltage at the PCM terminal 2U is 0.10 V or less for 5 s with the following condition met, the PCM determines that the MAF sensor circuit voltage is low.
MONITORING CONDITIONS
|
P0103:00
|
MAF sensor circuit high input
|
• The PCM monitors the input voltage from the MAF sensor when the engine is running. If the input voltage at the PCM terminal 2U is above 4.70 V for 5 s, the PCM determines that the MAF sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0106:00
|
MAP sensor No.2 circuit range/performance problem
|
• The following conditions remain for a continuous specified time when the battery voltage is 8 V or more:
|
P0107:00
|
MAP sensor No.2 circuit low input
|
• The PCM monitors the input voltage from the MAP sensor No.2. If the input voltage at the PCM terminal 1CQ is below 0.33 V for 4 s, the PCM determines that the MAP sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P0108:00
|
MAP sensor No.2 circuit high input
|
• The PCM monitors the input voltage from the MAP sensor No.2. If the input voltage at the PCM terminal 1CQ is above 4.20 V for 10 s, the PCM determines that the MAP sensor No.2 circuit has a malfunction.
|
P0111:00
|
IAT sensor No.1 circuit range/performance problem
|
• The difference between the intake air temperature measured by IAT sensor No.1 and IAT sensor No.2 exceeds 50 °C {90 °F}.
• The difference between the intake air temperature measured by IAT sensor No.1 and boost air temperature sensor exceeds 50 °C {90 °F}.
|
P0112:00
|
IAT sensor No.1 circuit low input
|
• The PCM monitors the IAT sensor No.1 signal. If the PCM detects that the IAT sensor No.1 voltage at the PCM terminal 2Y is below 0.10 V for 1 s, the PCM determines that the IAT sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0113:00
|
IAT sensor No.1 circuit high input
|
• The PCM monitors the IAT sensor No.1 signal. If the PCM detects that the IAT sensor No.1 voltage at the PCM terminal 2Y is above 4.90 V for 1 s, the PCM determines that the IAT sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0116:00
|
ECT sensor circuit range/performance problem
|
• The PCM monitors the maximum value and minimum value of engine coolant temperature when the engine is started and 5 min have been passed after leaving the vehicle 6 h or more. If difference between maximum and minimum values of engine coolant temperature is below 6 °C {11 °F} the PCM determines that there is an ECT sensor circuit range/performance problem.
MONITORING CONDITIONS
|
P0117:00
|
ECT sensor circuit low input
|
• The PCM monitors the ECT sensor signal. If the PCM detects that the ECT sensor voltage at the PCM terminal 1DC is below 0.13 V for 1 s, the PCM determines that the ECT sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0118:00
|
ECT sensor circuit high input
|
• The PCM monitors the ECT sensor signal. If the PCM detects that the ECT sensor voltage at the PCM terminal 1DC is above 4.93 V for 1 s, the PCM determines that the ECT sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0121:00
|
APP sensor No.1/No.2 correlation problem
|
• With the following conditions met, the output voltage of APP sensors No.1 and No.2 is compared, and the difference in the voltage is 0.5 V or more for a continuous 1 s:
MONITORING CONDITIONS
|
P0122:00
|
APP sensor No.1 circuit low input
|
• The PCM monitors the input voltage from APP sensor No.1 when the engine is running. If the input voltage at the PCM terminal 2AN is below 0.30 V for 0.5 s, the PCM determines that the APP sensor No.1 circuit input voltage is low.
MONITORING CONDITIONS
|
P0123:00
|
APP sensor No.1 circuit high input
|
• The PCM monitors the input voltage from APP sensor No.1 when the engine is running. If the input voltage at the PCM terminal 2AN is above 4.70 V for 0.5 s, the PCM determines that the APP sensor No.1 circuit input voltage is high.
MONITORING CONDITIONS
|
P0131:00
|
A/F sensor circuit low input
|
• The PCM monitors the input voltage from the A/F sensor when the engine is running. If the following PCM terminal voltage is below specified for 3 s, the PCM determines that the A/F sensor circuit voltage is low.
MONITORING CONDITIONS
|
P0132:00
|
A/F sensor circuit high input
|
• The PCM monitors the input voltage from the A/F sensor when the engine is running. If the following PCM terminal voltage is above specified for 3 s, the PCM determines that the A/F sensor circuit voltage is high.
MONITORING CONDITIONS
|
P0133:00
|
A/F sensor circuit no activity detected
|
• The PCM monitors the A/F sensor impedance when the following conditions are met. If the impedance is more than threshold (40 Ω (cold), 100 Ω (hot)) for 5 s, the PCM determines that A/F sensor is not activated.
MONITORING CONDITIONS
|
P0134:00
|
A/F sensor circuit problem
|
• If the PCM detects the A/F sensor voltage is below 0.10 V for 5 s with the following condition met, the PCM determines that the A/F sensor circuit has problem.
MONITORING CONDITIONS
|
P0154:00
|
Atmosphere learning malfunction in A/F sensor circuit
|
• The difference in the oxygen concentration between atmosphere and the A/F sensor output value is 35 % or more for a continuous 7 s.
MONITORING CONDITIONS
|
P0181:00
|
Fuel temperature sensor circuit range/performance problem
|
• The difference between the fuel temperature minimum value and maximum value is 1 °C {2 °F} or less for a continuous 3 s when the following conditions are met:
MONITORING CONDITIONS
|
P0182:00
|
Fuel temperature sensor circuit low input
|
• The PCM monitors the fuel temperature sensor signal. If the PCM detects that the fuel temperature sensor voltage at the PCM terminal 1CU is below 0.09 V for 1 s, the PCM determines that the fuel temperature sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0183:00
|
Fuel temperature sensor circuit high input
|
• The PCM monitors the fuel temperature sensor signal. If the PCM detects that the fuel temperature sensor voltage at the PCM terminal 1CU is above 4.90 V for 1 s, the PCM determines that the fuel temperature sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0191:00
|
Fuel pressure sensor circuit range/performance problem
|
• The PCM monitors the fuel pressure in the common rail and input signal from the fuel pressure sensor. If all of the following conditions is met for 20 s, the PCM determines that there is malfunction in the fuel pressure sensor range/performance malfunction.
• When the following conditions are met, the fuel pressure exceeds 240 MPa {2,447 kgf/cm2, 34,809 psi}:
MONITORING CONDITIONS
|
P0192:00
|
Fuel pressure sensor circuit low input
|
• If the input voltage at the PCM terminal 1AL is less than 0.57 V for 0.7 s, the PCM determines that the fuel pressure sensor circuit is low.
MONITORING CONDITIONS
|
P0193:00
|
Fuel pressure sensor circuit high input
|
• If the input voltage at the PCM terminal 1AL is more than 4.74 V for 0.7 s, the PCM determines that the fuel pressure sensor circuit is high.
MONITORING CONDITIONS
|
P0196:00
|
Engine oil temperature sensor circuit range/performance problem
|
• When the following conditions are met, the engine oil temperature is 20 °C {68 °F} or more for a continuous 1 s:
MONITORING CONDITIONS
|
P0197:00
|
Engine oil temperature sensor circuit low input
|
• The PCM monitors the input signal from the engine oil temperature sensor. If the voltage from the engine oil temperature sensor is below 0.1 V for 1 s, the PCM determines that the engine oil temperature sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0198:00
|
Engine oil temperature sensor circuit high input
|
• The PCM monitors the engine oil temperature sensor signal. If the PCM detects that the engine oil temperature sensor voltage at the PCM terminal 1DI is above 4.9 V for 1 s, the PCM determines that the engine oil temperature sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P0201:00
|
Fuel injector No.1 circuit operating abnormally
|
• The injection verification signal is not detected during the fuel injector No.1 operation when the following conditions are met:
MONITORING CONDITIONS
|
P0202:00
|
Fuel injector No.2 circuit operating abnormally
|
• The injection verification signal is not detected during the fuel injector No.2 operation when the following conditions are met:
MONITORING CONDITIONS
|
P0203:00
|
Fuel injector No.3 circuit operating abnormally
|
• The injection verification signal is not detected during the fuel injector No.3 operation when the following conditions are met:
MONITORING CONDITIONS
|
P0204:00
|
Fuel injector No.4 circuit operating abnormally
|
• The injection verification signal is not detected during the fuel injector No.4 operation when the following conditions are met:
MONITORING CONDITIONS
|
P0219:00
|
Engine overspeed condition
|
• An engine speed of 5,630 rpm or more continues for several seconds*
*: There is a slight difference of engine speed depending on the vehicle.
|
P0222:00
|
APP sensor No.2 circuit low input
|
• The PCM monitors the input voltage from APP sensor No.2 when the engine is running. If the input voltage at the PCM terminal 2AS is less than 0.20 V for 0.5 s, the PCM determines that the APP sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P0223:00
|
APP sensor No.2 circuit high input
|
• The PCM monitors the input voltage from APP sensor No.2 when the engine is running. If the input voltage at the PCM terminal 2AS is more than 4.7 V for 0.5 s, the PCM determines that the APP sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P0234:00
|
Small-type turbocharger overboost condition
|
• The difference between the target intake air pressure and the actual intake air pressure in the range of the small-type turbocharger less than the specified value for a continuous 7 s when the following conditions are met.
MONITORING CONDITIONS
|
P0236:00
|
MAP sensor No.1 circuit range/performance problem
|
• The following conditions remain for a continuous specified time when the battery voltage is 8 V or more:
|
P0237:00
|
MAP sensor No.1 circuit low input
|
• The PCM monitors the input voltage from the MAP sensor No.1. If the input voltage at the PCM terminal 1BK is below 0.33 V for 4 s, the PCM determines that the MAP sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0238:00
|
MAP sensor No.1 circuit high input
|
• The PCM monitors the input voltage from the MAP sensor No.1. If the input voltage at the PCM terminal 1BK is above 4.20 V for 10 s, the PCM determines that the MAP sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0299:00
|
Small-type turbocharger underboost condition
|
• The difference between the target intake air pressure and the actual intake air pressure in the range of the small-type turbocharger exceeds the specified value for a continuous 7 s when the following conditions are met:
MONITORING CONDITIONS
|
P02CA:00
|
Large-type turbocharger overboost condition
|
• The difference between the target intake air pressure and the actual intake air pressure in the range of the large-type turbocharger less than the specified value for a continuous 7 s when the following conditions are met.
MONITORING CONDITIONS
|
P02CB:00
|
Large-type turbocharger underboost condition
|
• The difference between the target intake air pressure and the actual intake air pressure in the range of the large-type turbocharger exceeds the specified value for a continuous 7 s when the following conditions are met.
MONITORING CONDITIONS
|
P0301:00
|
Cylinder No.1 misfire detected
|
• The misfire rate of specific cylinders for the crankshaft speed exceeds the specification for a continuous 16 s when the following conditions are met:
MONITORING CONDITIONS
|
P0302:00
|
Cylinder No.2 misfire detected
|
|
P0303:00
|
Cylinder No.3 misfire detected
|
|
P0304:00
|
Cylinder No.4 misfire detected
|
|
P0313:00
|
Misfire detected with low fuel
|
• “Injection amount cumulative value after lowering point E”, which is calculated by the PCM, exceeds the threshold value (larger than DTC P115A:00).
|
P0336:00
|
CKP sensor circuit range/performance problem
|
• CKP sensor signal is not input 56 times while the crankshaft rotates 20 times with the following conditions met:
MONITORING CONDITIONS
|
P0337:00
|
CKP sensor circuit problem
|
• There is no CKP sensor signal input while the crankshaft rotates 12 times.
MONITORING CONDITIONS
|
P0339:00
|
CKP sensor circuit range/performance problem
|
• When any of the following conditions is met:
|
P0341:00
|
CMP sensor circuit range/performance problem
|
• CMP sensor signal is not input 5 times while the crankshaft rotates 10 times with the following conditions met:
MONITORING CONDITIONS
|
P0342:00
|
CMP sensor circuit problem
|
• There is no CMP sensor signal input while the crankshaft rotates 5 and a half times when the following conditions are met:
MONITORING CONDITIONS
|
P0383:00
|
Glow control module circuit low input
|
• The PCM monitors the input voltage from the glow control module. If the input voltage is below 0.19 V for 1 s, the PCM determines that the glow control module circuit has a malfunction.
MONITORING CONDITIONS
|
P0384:00
|
Glow control module circuit high input
|
• The PCM monitors the input current from the glow control module. If the input current is above 5.9 A for 1 s, the PCM determines that the glow control module circuit has a malfunction.
MONITORING CONDITIONS
|
P039A:00
|
Cylinder No. 1 compression pressure is too low
|
• Decrease in compression pressure of each cylinder is detected during deceleration
|
P03A4:00
|
Cylinder No. 2 compression pressure is too low
|
|
P03AE:00
|
Cylinder No. 3 compression pressure is too low
|
|
P03B8:00
|
Cylinder No. 4 compression pressure is too low
|
|
P0401:00
|
EGR flow insufficient detected
|
• When the following condition is met, the EGR volume is lower than the specification for the target value for a continuous 8 s:
MONITORING CONDITIONS
|
P0402:00
|
EGR flow excessive detected
|
• When the following condition is met, the EGR volume is higher than the specification for the target value for a continuous 8 s:
MONITORING CONDITIONS
|
P0404:00
|
Circuit malfunction in EGR valve DC motor control system
|
• The EGR valve DC motor drive current exceeds the specification for a continuous 3 s when the following condition is met:
MONITORING CONDITIONS
|
P0405:00
|
EGR valve position sensor circuit low input
|
• If the input voltage at the PCM terminal 1AQ is less than 0.2 V for 5 s, the PCM determines that the EGR valve position sensor circuit is low.
|
P0406:00
|
EGR valve position sensor circuit high input
|
• If the input voltage at the PCM terminal 1AQ is more than 4.9 V for 1 s, the PCM determines that the EGR valve position sensor circuit is high.
MONITORING CONDITIONS
|
P0421:00
|
Warm up catalyst system efficiency below threshold
|
• The difference between the exhaust gas temperature before and after passing the catalytic converter is specified value or less for a continuous 60 to 80 s when the following conditions are met:
MONITORING CONDITIONS
|
P0471:00
|
Exhaust gas pressure sensor No.1 circuit range/performance problem
|
• The following conditions remain for a continuous specified time when the battery voltage is 8 V or more:
|
P0472:00
|
Exhaust gas pressure sensor No.1 circuit low input
|
• If the input voltage at the PCM terminal 1CE is less than 0.33 V for 4 s, the PCM determines that the exhaust gas pressure sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0473:00
|
Exhaust gas pressure sensor No.1 circuit high input
|
• If the input voltage at the PCM terminal 1CE is more than 4.2 V for 10 s, the PCM determines that the exhaust gas pressure sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0480:00
|
Fan control module No.1 control circuit problem
|
• The PCM monitors the input voltage from the fan control module No.1. If the voltage at the PCM terminal 2BG remains low or high for 5 s, the PCM determines that the fan control circuit has a malfunction.
|
P0481:00
|
Fan control module No.2 control circuit problem
|
• The PCM monitors the input voltage from the fan control module No.2. If the voltage at the PCM terminal 2AW remains low or high for 5 s, the PCM determines that the fan control circuit has a malfunction.
|
P0488:00
|
Duty signal error in EGR valve control system
|
• When the following conditions are met, the EGR valve control duty value is 90 % or more for a continuous 2 s:
MONITORING CONDITIONS
|
P0500:00
|
VSS circuit problem
|
• The vehicle speed signal input from the DSC HU/CM is incorrect for a continuous 5 s when the following condition is met:
MONITORING CONDITIONS
|
P0522:00
|
Engine oil pressure sensor circuit low input
|
• If the input voltage at the PCM terminal 1DM is less than 0.33 V for 4 s, the PCM determines that the engine oil pressure sensor circuit is low.
MONITORING CONDITIONS
|
P0523:00
|
Engine oil pressure sensor circuit high input
|
• If the input voltage at the PCM terminal 1DM is more than 4.2 V for 10 s, the PCM determines that the engine oil temperature sensor circuit is high.
MONITORING CONDITIONS
|
P0524:00
|
Engine oil pressure too low
|
• If the engine oil pressure is below 30 kPa {0.31 kgf/cm2, 4.4 psi}, the PCM determines that the engine oil pressure control circuit problem.
|
P0532:00*1
|
Refrigerant pressure sensor circuit low input
|
• The PCM monitors input voltage from the refrigerant pressure sensor when the ignition switch is ON. If the input voltage at the PCM terminal 2BH is below 0.15 V, the PCM determines that the refrigerant pressure sensor circuit has a malfunction.
|
P0533:00*1
|
Refrigerant pressure sensor circuit high input
|
• The PCM monitors the input voltage from the refrigerant pressure sensor when the ignition switch is ON. If the input voltage at the PCM terminal 2BH is above 4.9 V, the PCM determines that the refrigerant pressure sensor circuit has a malfunction.
|
P053B:00
|
Blow-by heater relay control circuit low input
|
• The PCM monitors input voltage from the blow-by heater relay. If the input voltage is below 0.19 V for 1 s, the PCM determines that the blow-by heater relay circuit has a malfunction.
MONITORING CONDITIONS
|
P053C:00
|
Blow-by heater relay control circuit high input
|
• The PCM monitors input current from the blow-by heater relay. If the input current is above 1.5 A for 1 s, the PCM determines that the blow-by heater relay circuit has a malfunction.
MONITORING CONDITIONS
|
P0545:00
|
Exhaust gas temperature sensor No.1 circuit low input
|
• The PCM monitors the exhaust gas temperature sensor No.1 signal. If the PCM detects that the exhaust gas temperature sensor No.1 voltage at the PCM terminal 1CI is below 0.24 V for 1 s, the PCM determines that the exhaust gas temperature sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0546:00
|
Exhaust gas temperature sensor No.1 circuit high input
|
• The PCM monitors the exhaust gas temperature sensor No.1 signal. If the PCM detects that the exhaust gas temperature sensor No.1 voltage at the PCM terminal 1CI is above 4.96 V for 3 s, the PCM determines that the exhaust gas temperature sensor No.1 circuit has a malfunction.
MONITORING CONDITIONS
|
P0555:00
|
Power brake unit vacuum sensor circuit problem
|
• The PCM monitors the power brake unit vacuum sensor signal voltage while the ignition switch is ON. If the PCM detects the power brake unit vacuum sensor voltage is below 0.15 V or above 4.8 V, the PCM determines that the power brake unit vacuum sensor circuit has problem.
|
P055F:00
|
Engine oil pressure control circuit low oil pressure
|
TYPE A (PCM part number: SHY3-18881-A—I, SHY4-18881-A—I, SHY5-18881-A—I, SHY6-18881-A—I, SHYF-18881-A—B, SHYG-18881-A—B, SHYH-18881-A—B, SH3E-18881-A—M, SH3F-18881-A—M, SH3G-18881-A—M, SH3H-18881-A—K, SH3J-18881-A—K, SH3K-18881-A—J, SH3T-18881-A—J, SH3L-18881-A—J, SH3N-18881-A—J)
• The engine oil pressure is the specified value or less after the specified time has elapsed since the engine was started.
TYPE B (PCM part number: except SHY3-18881-A—I, SHY4-18881-A—I, SHY5-18881-A—I, SHY6-18881-A—I, SHYF-18881-A—B, SHYG-18881-A—B, SHYH-18881-A—B, SH3E-18881-A—M, SH3F-18881-A—M, SH3G-18881-A—M, SH3H-18881-A—K, SH3J-18881-A—K, SH3K-18881-A—J, SH3T-18881-A—J, SH3L-18881-A—J, SH3N-18881-A—J)
• The engine oil pressure is the specified value or less after the specified time has elapsed since the engine was started.
|
P0571:00
|
Brake switch circuit problem
|
• Any of the following conditions is detected 5 times continuously:
|
P057F:00
|
Power system: Battery deterioration
|
• The battery charge/discharge flow exceeds the specification.
|
P058A:00
|
Current sensor: Function malfunction
|
• Error signal from the current sensor is received.
|
P0601:00
|
PCM memory check sum error
|
• The PCM detects the internal malfunction.
|
P0602:00
|
PCM programming error
|
• No configuration data in the PCM.
|
P0605:00
|
PCM memory check sum error
|
• The PCM detects the internal malfunction for a continuous 5 s.
|
P0606:00
|
PCM processor error
|
• PCM internal CPU malfunction.
MONITORING CONDITIONS
|
P0607:00
|
Control module performance problem
|
• PCM internal malfunction.
MONITORING CONDITIONS
|
P0610:00
|
PCM vehicle configuration error
|
• PCM data configuration error.
|
P0615:00
|
Starter relay circuit problem
|
• The PCM records DTCs when the number of times the engine has been started reaches the warrantied performance frequency for the starter or starter relay.
|
P062A:00
|
Suction control valve circuit problem
|
• Any of following conditions occurs:
|
P062B:00
|
PCM internal malfunction
|
• PCM detects malfunction in internal processor with the following conditions met:
MONITORING CONDITIONS
|
P0642:00
|
Constant voltage power supply circuit low input
|
• When the following condition is met, the output voltage of the 5 V power supply terminal 3.875 V or less for a continuous 1 s:
MONITORING CONDITIONS
|
P0643:00
|
Constant voltage power supply circuit high input
|
• When the following condition is met, the output voltage of the 5 V power supply terminal exceeds 5.125 V for a continuous 1 s:
MONITORING CONDITIONS
|
P0646:00*1
|
A/C relay circuit low input
|
• When the following conditions are met, PCM detects that the A/C relay voltage is approx. 0 V for a continuous 5 s:
MONITORING CONDITIONS
|
P0647:00*1
|
A/C relay circuit high input
|
• When the following conditions are met, PCM detects that the A/C relay voltage is approx. 5 V for a continuous 5 s:
MONITORING CONDITIONS
|
P0652:00
|
Constant voltage power supply control circuit low input
|
• When the following condition is met, the output voltage of the 5 V power supply terminal is 3.875 V or less for a continuous 1 s:
MONITORING CONDITIONS
|
P0653:00
|
Constant voltage power supply control circuit high input
|
• When the following condition is met, the output voltage of the 5 V power supply terminal exceeds 5.125 V for a continuous 1 s:
MONITORING CONDITIONS
|
P0668:00
|
PCM internal temperature sensor circuit low input
|
• PCM internal temperature sensor malfunction.
|
P0669:00
|
PCM internal temperature sensor circuit high input
|
• PCM internal temperature sensor malfunction.
|
P0670:00
|
Glow control module control circuit problem
|
• When the following conditions are met, the glow control module circuit malfunctions for a continuous 5 s:
MONITORING CONDITIONS
|
P0671:00
|
Glow plug No.1 control circuit problem
|
• If the input voltage is below 5 V for 5 s, the PCM determines that the glow plug No.1 circuit problem.
MONITORING CONDITIONS
|
P0672:00
|
Glow plug No.2 control circuit problem
|
• If the input voltage is below 5 V for 5 s, the PCM determines that the glow plug No.2 circuit problem.
MONITORING CONDITIONS
|
P0673:00
|
Glow plug No.3 control circuit problem
|
• If the input voltage is below 5 V for 5 s, the PCM determines that the glow plug No.3 circuit problem.
MONITORING CONDITIONS
|
P0674:00
|
Glow plug No.4 control circuit problem
|
• If the input voltage is below 5 V for 5 s, the PCM determines that the glow plug No.4 circuit problem.
MONITORING CONDITIONS
|
P0683:00
|
Glow control module control circuit problem
|
• If the following conditions are met, the PCM determines that there is the glow control module control circuit problem.
MONITORING CONDITIONS
|
P0684:00
|
Glow control module control circuit communication error
|
• When the following conditions are met, the input signal pattern of the glow control module is incorrect for a continuous 5 s:
MONITORING CONDITIONS
|
P06B8:00
|
Internal control module non-volatile RAM error
|
• PCM internal EEPROM malfunction.
|
P06DB:00
|
Engine oil solenoid valve circuit low input
|
• If the PCM detects that the engine oil solenoid valve voltage at the PCM terminal 1CH is 0.19 V or less for 1 s with the following condition met, the PCM determines that the engine oil solenoid valve circuit voltage is low.
MONITORING CONDITIONS
|
P06DC:00
|
Engine oil solenoid valve control circuit high input
|
• If the PCM detects that the engine oil solenoid valve current at the PCM terminal 1CH is 5.9 A or more for 1 s with the following condition met, the PCM determines that the engine oil solenoid valve circuit voltage is high.
MONITORING CONDITIONS
|
P06DD:00
|
Engine oil pressure switch control circuit high input
|
• When the following condition is met, the engine oil pressure is exceeds 250 kPa {2.55 kgf/cm2, 36.3 psi}:
MONITORING CONDITIONS
|
P06DE:00
|
Engine oil pressure switch control circuit low input
|
• When the following condition is met, the engine oil pressure is 250 kPa {2.55 kgf/cm2, 36.3 psi} or less:
MONITORING CONDITIONS
|
P0703:00
|
Brake switch input circuit problem
|
• The PCM monitors the input signal from the brake switch No.1. If the input signal does not change while following decelerating 8 times, the PCM determines that there is a brake switch No.1 input circuit problem.
MONITORING CONDITIONS
|
P0704:00*2
|
CPP switch input circuit problem
|
• The PCM monitors changes in input voltage from the CPP switch. If the PCM does not detect a voltage change while the vehicle runs with vehicle speed above 30 km/h {19 mph} and stops 10 times alternately, the PCM determines that the CPP switch circuit has a malfunction.
|
P07BE:00*2
|
Transmission indeterminate failure (failed to neutral)
|
• Correlation malfunction between neutral switches No.1 and No.2.
|
P0850:00*2
|
Neutral switch No.1 input circuit problem
|
• The PCM monitors changes in input voltage from the neutral switch No.1. If the PCM does not detect a voltage change while driving the vehicle at a vehicle speed above 30 km/h {19 mph}and clutch pedal is pressed and released 10 times repeatedly, the PCM determines that the neutral switch No.1 circuit has a malfunction.
|
P0A0F:00
|
Engine failed to restart
|
• Any of following conditions occurs:
|
P0A8D:00
|
Power supply system circuit low input
|
• Any one of the following conditions is met:
|
P0A94:00
|
DC-DC converter: control circuit signal error
|
• Internal malfunction signal from DC-DC converter via front body control module (FBCM) is received.(CAN/LIN communication).
• Input signal from the DC-DC converter limits the pressure increase time.
• Input signal from the DC-DC converter does not implement pressure increase after a pressure increase command to the DC-DC converter.
|
P111A:00
|
Engine coolant temperature is high
|
• The engine coolant temperature is 110 °C {230 °F} or more for 2.5 s.
|
P1140:00
|
Sedimentor switch control circuit range/performance problem
|
• The level of accumulated water in the fuel filter exceeds the specification (sedimentor switch turns on in this case).
|
P115A:00
|
Lack of remaining fuel (output restriction)
|
• “Injection amount cumulative value after lowering point E”, which is calculated by the PCM, exceeds the threshold value.
|
P115B:00
|
Lack of remaining fuel (fuel injection pause)
|
• “Injection amount cumulative value after lowering point E”, which is calculated by the PCM, exceeds the threshold value (larger than DTC P0313:00).
|
P117A:00
|
Record of torque restriction for piston protection
|
• The engine oil pressure is the specified value or less for a continuous 8 s.
• The vehicle is driven continuously for a certain period of time at low engine speed and high load.
|
P1196:00
|
Main relay control circuit problem
|
• Main relay control voltage is 10 V or less while the ignition switch is off.
|
P1200:00
|
Fuel injection amount learning not completed
|
• Fuel injector injection amount correction is not completed correctly.
|
P1260:00
|
Immobilizer system problem
|
• The start stop unit detects an immobilizer system malfunction.
|
P1282:00
|
Common rail control system problem
|
• When the following conditions are met, the common rail fuel pressure value exceeds 250 MPa {2,549 kgf/cm2, 36,260 psi} or the fuel pressure value exceeds the value calculated by the PCM based on the engine speed for a continuous 1 s.
MONITORING CONDITIONS
|
P1303:00
|
EGR cooler bypass valve full closing angle malfunction
|
• EGR cooler bypass valve position sensor signal voltage is 1.2 V or more, or 0.65 V or less with the ignition switched off and EGR cooler bypass valve fully closed.
|
P1329:00
|
Common rail pressure higher than desired (engine running)
|
• When the following conditions are met, the common rail fuel pressure value exceeds 250 MPa {2,549 kgf/cm2, 36,260 psi} or the fuel pressure value exceeds the value calculated by the PCM based on the engine speed for a continuous 60 s.
MONITORING CONDITIONS
• When the following conditions are met, the common rail fuel pressure value exceeds 217 MPa {2,213 kgf/cm2, 31,473 psi} or the fuel pressure value exceeds the value calculated by the PCM based on the engine speed for a continuous 60 s.
MONITORING CONDITIONS
|
P1336:00
|
CKP sensor/CMP sensor malfunction
|
• If the phase difference between the CKP sensor and CMP sensor exceeds the specified value, the PCM determines that the timing chain is stretched and stores DTC P1336:00.
|
P1378:00
|
Fuel injector circuit low input
|
• When the following conditions are met, the DC-DC converter output voltage 120 V or less:
MONITORING CONDITIONS
|
P1379:00
|
Fuel injector circuit high input
|
• When the following conditions are met, the DC-DC converter output voltage exceeds 250 V:
MONITORING CONDITIONS
|
P1589:00
|
Intake shutter valve control duty signal error
|
• Intake shutter valve actuator control duty value is 90 % for a continuous 2 s.
|
P1675:00
|
Fuel injector code not programmed
|
• Fuel injector code has not been programmed to the PCM.
|
P1676:00
|
Fuel injector code mistakenly programmed
|
• Fuel injector code is not programmed correctly to the PCM.
|
P167B:00
|
Fuel injection amount learning not completed in fuel injection system
|
• Fuel injector injection amount correction is not completed.
|
P176E:00*2
|
Clutch stroke sensor/starter interlock switch correlation problem
|
• Correlation malfunction between clutch stroke sensor and starter interlock switch.
|
P1905:00
|
Check connector circuit low input
|
• PCM detects that the check connector voltage is approx. 0 V for a continuous 5 s.
|
P2002:00
|
Diesel particulate filter function decreased
|
• When the following conditions are met, a difference in the pressure before and after passing the diesel particulate filter of less than the specified value is detected:
MONITORING CONDITIONS
|
P2032:00
|
Exhaust gas temperature sensor No.2 circuit low input
|
• The PCM monitors the exhaust gas temperature sensor No.2 signal. If the PCM detects that the exhaust gas temperature sensor No.2 voltage at the PCM terminal 1CA is below 0.24 V for 1 s, the PCM determines that the exhaust gas temperature sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P2033:00
|
Exhaust gas temperature sensor No.2 circuit high input
|
• The PCM monitors the exhaust gas temperature sensor No.2 signal. If the PCM detects that the exhaust gas temperature sensor No.2 voltage at the PCM terminal 1CA is above 4.96 V for 3 s, the PCM determines that the exhaust gas temperature sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P2101:00
|
Intake shutter valve control circuit overcurrent
|
• The intake air shutter valve drive current exceeds the specification for a continuous 3 s when the following condition is met:
MONITORING CONDITIONS
|
P2105:00
|
Intake air shutter valve actuator control system malfunction (forced engine shutdown)
|
• After switching the ignition off, the PCM detects that the engine speed has not decreased for a specified time.
|
P2118:00
|
Intake shutter valve control duty signal error
|
• The intake air shutter valve control duty value is 90 % for a continuous 2 s.
|
P2146:00
|
Fuel injector No.1 and No.4 circuit abnormal operation
|
• When the following condition is met, the PCM detects the control current at fuel injectors No.1 and No.4 as less than the specified value 6 times:
MONITORING CONDITIONS
|
P2147:00
|
Fuel injector No.1 and No.4 circuit low input
|
• When the following condition is met, the PCM detects the control current at fuel injectors No.1 and No.4 as exceeding 35 A4 times or control voltage at fuel injectors No.1 and No.4 as 40 V or less4 times:
MONITORING CONDITIONS
|
P2148:00
|
Fuel injector No.1 and No.4 circuit high input
|
• When the following condition is met, the PCM detects the control current at fuel injectors No.1 and No.4 as exceeding 10 A4 times:
MONITORING CONDITIONS
|
P2149:00
|
Fuel injector No.2 and No.3 circuit abnormal operation
|
• When the following condition is met, the PCM detects the control current at fuel injectors No.2 and No.3 as less than the specified value 6 times:
MONITORING CONDITIONS
|
P2150:00
|
Fuel injector No.2 and No.3 circuit low input
|
• When the following condition is met, the PCM detects the control current at fuel injectors No.2 and No.3 as exceeding 35 A4 times or control voltage at fuel injectors No.2 and No.3 as 40 V or less4 times:
MONITORING CONDITIONS
|
P2151:00
|
Fuel injector No.2 and No.3 circuit high input
|
• When the following condition is met, the PCM detects the control current at fuel injectors No.2 and No.3 as exceeding 10 A4 times:
MONITORING CONDITIONS
|
P2227:00
|
BARO sensor circuit range/performance problem
|
• The following conditions remain for a continuous specified time when the battery voltage is 8 V or more:
|
P2228:00
|
BARO sensor circuit low input
|
• The PCM monitors input voltage from the BARO sensor. If the input voltage is below 1.3 V for 3 s, the PCM determines that the BARO sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P2229:00
|
BARO sensor circuit high input
|
• The PCM monitors input voltage from the BARO sensor. If the input voltage is above 4.7 V for 3 s, the PCM determines that the BARO sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P2262:00
|
Small-type turbocharger area control system: turbocharger malfunction
|
• The PCM detects that the boost pressure is low even though the exhaust gas pressure is high while the boost control is performed using the small-type turbocharger.
|
P2263:00
|
Regulating valve control circuit range/performance problem
|
• The following conditions are met, the difference between the target regulating valve opening angle and the actual regulating valve opening angle is 10 mm {0.39 in} or more for a continuous 3 s:
• The following conditions are met, the difference between the target regulating valve opening angle and the actual regulating valve opening angle is -10 mm {-0.39 in} or less for a continuous 3 s:
|
P2299:00
|
Accelerator pedal: spring back malfunction
|
• When under the following conditions it is detected that the brake pedal is depressed during driving for the specified time*.
*: Specified time is 0.6—10 s according to braking force calculated in PCM.
|
P242C:00
|
Exhaust gas temperature sensor No.3 circuit low input
|
• The PCM monitors the exhaust gas temperature sensor No.3 signal. If the PCM detects that the exhaust gas temperature sensor No.3 voltage at the PCM terminal 1BW is below 0.24 V for 1 s, the PCM determines that the exhaust gas temperature sensor No.3 circuit has a malfunction.
MONITORING CONDITIONS
|
P242D:00
|
Exhaust gas temperature sensor No.3 circuit high input
|
• The PCM monitors the exhaust gas temperature sensor No.3 signal. If the PCM detects that the exhaust gas temperature sensor No.3 voltage at the PCM terminal 1BW is above 4.96 V for 3 s, the PCM determines that the exhaust gas temperature sensor No.3 circuit has a malfunction.
MONITORING CONDITIONS
|
P242F:00
|
Diesel particulate filter excess accumulation (exceeded acceptable amount)
|
• Amount of accumulated soot exceeds 17 g/l {1.06 lb/ft3} for 125 s because of diesel particulate filter clogging.
|
P243C:00
|
Abnormal DPF regeneration interval short distance
|
• The following conditions are met 3 times:
|
P244A:00
|
Exhaust gas pressure sensor No.2 range/performance problem
|
• When the following conditions are met, a difference in the pressure before and after passing the diesel particulate filter of 0.2 kPa {0.002 kgf/cm2, 0.03 psi} or less is detected for a continuous 10 s:
MONITORING CONDITIONS
|
P2452:00
|
Signal malfunction in exhaust gas pressure sensor No.2
|
• Difference in pressure is ±5 kPa {±0.05 kgf/cm2, ±0.7 psi} or more while the engine is stopped.
|
P2453:00
|
Pressure malfunction in exhaust gas pressure sensor No.2
|
• Difference in pressure is 100 kPa {1.02 kgf/cm2, 14.5 psi} or more while the engine is running.
|
P2454:00
|
Exhaust gas pressure sensor No.2 circuit low input
|
• If the input voltage at the PCM terminal 1Z is less than 0.52 V for 30 s, the PCM determines that the exhaust gas pressure sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P2455:00
|
Exhaust gas pressure sensor No.2 circuit high input
|
• If the input voltage at the PCM terminal 1Z is more than 4.81 V for 30 s, the PCM determines that the exhaust gas pressure sensor No.2 circuit has a malfunction.
MONITORING CONDITIONS
|
P2456:00
|
Characteristic malfunction in exhaust gas pressure sensor No.2
|
• When the following conditions are met, a difference in the pressure before and after passing the diesel particulate filter of less than 0.1 kPa {0.001 kgf/cm2, 0.01 psi} is detected for 16 times:
MONITORING CONDITIONS
|
P2458:00
|
Diesel particulate filter excess accumulation (mid)
|
• PCM detects that the soot accumulation amount above 10 g/l {0.6 Ib/ft3}.
|
P245A:00
|
EGR cooler bypass valve control: Drive circuit malfunction
|
• The EGR cooler bypass valve drive current exceeds the specification for a continuous 3 s when the following condition is met:
MONITORING CONDITIONS
|
P245B:00
|
EGR cooler bypass valve control: duty signal malfunction
|
• If the duty value is 95 % for 2 s, the PCM determines that there is a EGR cooler bypass valve actuator control system range/performance problem.
|
P2463:00
|
Diesel particulate filter excess accumulation (large)
|
• PCM detects that the soot accumulation amount above 13 g/l {0.8 Ib/ft3} for a continuous 125 s.
|
P246C:00
|
Engine oil dilution, oil pressure decreased
|
• The amount of engine oil dilution exceeds the specified value (fluctuates by ambient temperature).
|
P2494:00
|
EGR cooler bypass valve position sensor circuit low input
|
• If the input voltage at the PCM terminal 1AV is less than 0.2 V for 1 s, the PCM determines that the EGR cooler bypass valve position sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P2495:00
|
EGR cooler bypass valve position sensor circuit high input
|
• If the input voltage at the PCM terminal 1AV is more than 4.9 V for 1 s, the PCM determines that the EGR cooler bypass valve position sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P24A5:00
|
EGR cooler bypass valve control: EGR cooler bypass valve (stuck)
|
• When all of the following conditions are met, the EGR cooler bypass valve operation does not conform to the target value.
• When the EGR cooler bypass valve fully closes from the open condition, the EGR cooler bypass valve position sensor output value is not that for the fully closed condition.
|
P2502:00
|
Generator system: Malfunction in voltage generated by generator
|
• The voltage generated by the generator is 17 V or higher and the battery voltage is 11 V or less for a continuous specified time.
|
P2503:00
|
Generator system: Voltage generated by generator is low
|
• A condition continues for a specified period of time in which the target generator output current calculated by the PCM is 20A or more and the generator output voltage is 8.5 V or less.
|
P2504:00
|
Generator system: Voltage generated by generator is high
|
• The voltage generated by the generator is 18.5 V or higher or the battery voltage is 16 V or higher for a continuous specified time.
|
P2507:00
|
PCM battery voltage low input
|
• The PCM monitors the voltage of backup battery positive terminal. If the PCM detects that the battery positive terminal voltage is below 6 V for 5 s, the PCM determines that the backup voltage circuit has a malfunction.
MONITORING CONDITIONS
|
P252F:00
|
Engine oil level too high
|
• The amount of engine oil dilution exceeds 1,661 g {58.59 oz} during the diesel particulate filter regeneration control.
|
P253F:00
|
Engine oil deteriorated
|
Type A (PCM part number: SH3E-18881 (suffix: to E), SH3F-18881 (suffix: to E), SH3G-18881 (suffix: to E), SH3H-18881 (suffix: to D), SH3J-18881 (suffix: to D), SH3K-18881 (suffix: to D), SH3N-18881 (suffix: to D), SH3L-18881 (suffix: to D), SH3T-18881 (suffix: to D), SH01-18881 (suffix: to S), SH1A-18881 (suffix: to S), SH1J-18881 (suffix: to S))
• The amount of engine oil dilution exceeds 2,236 g {78.87 oz} during the diesel particulate filter regeneration control.
• The amount of engine oil dilution exceeds the specified value (fluctuates by ambient temperature).
• With the following driving conditions met, the engine oil pressure decreases 50 kPa {0.51 kgf/cm2, 7.3 psi} or more compared to when the engine oil was replaced.
MONITORING CONDITIONS
Type B (PCM part number: SH3E-18881 (suffix: F—M), SH3F-18881 (suffix: F—M), SH3G-18881 (suffix: F—M), SH3H-18881 (suffix: E—L), SH3J-18881 (suffix: E—K), SH3K-18881 (suffix: E—J), SH3L-18881 (suffix: E—J), SH3T-18881 (suffix: E—J), SHY3-188K2 (suffix: to I), SHY4-188K2 (suffix: to I), SHY5-188K2 (suffix: to I), SHY6-188K2 (suffix: to I), SHYF-188K2 (suffix: to B), SHYG-188K2 (suffix: to B), SHYH-188K2 (suffix: to B), SH3N-188K2 (suffix: F—J))
• The amount of engine oil dilution exceeds 2,236 g {78.87 oz} during the diesel particulate filter regeneration control.
• The amount of engine oil dilution exceeds the specified value (fluctuates by ambient temperature).
• With the following driving conditions met, the engine oil pressure decreases 40 kPa {0.41 kgf/cm2, 5.8 psi} or more compared to when the engine oil was replaced.
MONITORING CONDITIONS
Type C (except (type A or type B))
• The amount of engine oil dilution exceeds 2,236 g {78.87 oz} during the diesel particulate filter regeneration control.
• The amount of engine oil dilution exceeds the specified value (fluctuates by ambient temperature).
• With the following driving conditions met, the engine oil pressure decreases 60 kPa {0.61 kgf/cm2, 8.7 psi} or more compared to when the engine oil was replaced
MONITORING CONDITIONS
|
P2564:00
|
Regulating valve position sensor circuit low input
|
• If the input voltage at the PCM terminal 1BP is less than 0.2 V for 1 s, the PCM determines that the regulating valve position sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P2565:00
|
Regulating valve position sensor circuit high input
|
• If the input voltage at the PCM terminal 1BP is more than 4.9 V for 1 s, the PCM determines that the regulating valve position sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P258B:00
|
Power brake unit vacuum sensor control circuit range/performance problem
|
• The PCM determines that the measurement performance of the power brake unit vacuum sensor and the vacuum generation performance of the vacuum pump, calculated from the engine speed, are deteriorated.
|
P2610:00
|
Instrument cluster internal engine off timer performance problem
|
• Instrument cluster internal engine off timer is damaged.
|
P2621:00
|
Intake shutter valve position sensor circuit low input
|
• If the input voltage at the PCM terminal 1BA is less than 0.2 V for 1 s, the PCM determines that the intake shutter valve position sensor circuit has a malfunction.
MONITORING CONDITIONS
|
P2622:00
|
Intake shutter valve position sensor circuit high input
|
• If the input voltage at the PCM terminal 1BA is more than 4.82 V for 1 s, the PCM determines that the intake shutter valve position sensor circuit has a malfunction.
MONITORING CONDITIONS
|
U0073:00
|
CAN system communication error (HS CAN)
|
• Malfunction in CAN bus communication line.
|
U0074:00*3
|
CAN system communication error (local CAN between PCM and TCM)
|
• Malfunction in CAN bus communication line.
|
U0101:00*3
|
CAN communication: communication error to TCM
|
• Communication error between the PCM and TCM continues for 5 s or more.
|
U0121:00
|
CAN communication: communication error to DSC HU/CM
|
• Communication error between the PCM and DSC HU/CM continues for 5 s or more.
|
U0131:00
|
CAN communication: communication error to EPS control module
|
• Communication error between the PCM and EPS control module continues for 5 s or more.
|
U0140:00
|
CAN communication: communication error to front body control module (FBCM)
|
• Communication error between the PCM and front body control module (FBCM) continues for 5 s or more.
|
U0151:00
|
CAN communication: communication error to SAS control module
|
• Communication error between the PCM and SAS control module continues for 5 s or more.
|
U0155:00
|
CAN communication: communication error to instrument cluster
|
• Communication error between the PCM and instrument cluster continues for 5 s or more.
|
U0214:00
|
CAN communication: communication error to start stop unit
|
• Communication error between the PCM and start stop unit continues for 5 s or more.
|
U0235:00
|
CAN communication: communication error to laser sensor
|
• Communication error between the PCM and laser sensor continues for 5 s or more.
|
U0298:00
|
CAN/LIN communication system: DC-DC converter information communication error with front body control module (FBCM)
|
• PCM detects a DC-DC converter information communication error from front body control module (FBCM).
|
U0302:00*3
|
TCM processor error
|
• When any of the following conditions is met:
|
U0315:00
|
DSC HU/CM error
|
• When any of the following conditions is met:
|
U0320:00
|
EPS control module error
|
• When any of the following conditions is met:
|
U0323:00
|
Instrument cluster error
|
• When any of the following conditions is met:
|
U0336:00
|
SAS control module error
|
• When any of the following conditions is met:
|
U0338:00
|
Start stop unit error
|
• When any of the following conditions is met:
|
U0433:00
|
Abnormal message from rear body control module (RBCM)
|
• Correct data cannot be received from rear body control module (RBCM).
|
U2300:00
|
Global central configuration error
|
• Any of following conditions occurs:
|
U3000:41
|
PCM processor error
|
• The following conditions are met:
|