DTC U3000:09 [BLIND SPOT MONITORING (BSM)]


id0902i3393100

System malfunction location

BSM control module internal malfunction

Detection condition
•  The BSM control module detected a malfunction inside the voltage control oscillator.
Fail-safe
•  BSM is stopped.
Possible cause
•  BSM control module malfunction
System wiring diagram

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM DTC INSPECTION AND VERIFY IF MALFUNCTIONING PART IS BSM CONTROL MODULE
•  Clear BSM control module DTCs using the M-MDS.
•  Perform the DTC inspection for the BSM control module using the M-MDS.
•  Is the DTC U3000:09 displayed?
Yes
Replace the BSM control module, then go to the next step.
No
Go to the next step.
2
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.