DTC U0534:68 [BLIND SPOT MONITORING (BSM)]


id0902i3393400

Caution
•  Configuration cannot be implemented correctly if only the blind spot monitoring (BSM) control module (LH) is replaced. When replacing the blind spot monitoring (BSM) control module (LH), it is necessary to replace the blind spot monitoring (BSM) control module (RH) at the same time.

System malfunction location

Error signal received from BSM control module (RH)

Detection condition
•  The BSM control module (LH) received an error signal from the BSM control module (RH).
Fail-safe
•  BSM is stopped.
Possible cause
•  BSM control module (RH) malfunction
•  BSM control module (LH) malfunction
System wiring diagram

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM DTC INSPECTION AND VERIFY IF MALFUNCTIONING PART IS BSM CONTROL MODULE (RH)
•  Clear the BSM control module (LH) DTCs using the M-MDS.
•  Perform the DTC inspection for the BSM control module (LH) using the M-MDS.
•  Is the DTC U0534:68 displayed?
Yes
Replace the BSM control module (RH), then go to the next step.
No
Go to Step 3.
2
PERFORM DTC INSPECTION AND VERIFY IF MALFUNCTIONING PART IS BSM CONTROL MODULE (LH)
•  Clear the BSM control module (LH) DTCs using the M-MDS.
•  Perform the DTC inspection for the BSM control module (LH) using the M-MDS.
•  Is the DTC U0534:68 displayed?
Yes
Replace the BSM control module, then go to the next step.
No
Go to the next step.
3
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.