MAIN RELAY [WITH CYLINDER DEACTIVATION (SKYACTIV-G 2.0, SKYACTIV-G 2.5)]


id0140m2008300


Purpose/Function

•  Supplies power to each part.
•  Supplies battery voltage to each part based on the signals from the PCM even though the ignition is switched ON or off.

Construction

•  Installed in the relay box (LH).
ac5uun00002726

Operation

•  After the contact point is on battery voltage is supplied to the coil based on the signals from the PCM.
ac5wzn00002424

Fail-safe

•  Function not equipped.