AIR FUEL RATIO (A/F) SENSOR HEATER CONTROL [WITH CYLINDER DEACTIVATION (SKYACTIV-G 2.0, SKYACTIV-G 2.5)]
id0140m2785500
Outline
Block Diagram
ac5wzn00005479
|
Operation
Normal control
Output duty ratio |
Control condition |
---|---|
0%
|
When any of the following conditions is met
• Ignition switched off
• Engine stopped (excludes engine stop by i-stop control)
• Engine start (cranking)
|
0―100%
(Duty ratio determined by measuring the element temperature by the A/F sensor heater element impedance)
|
• After engine warm-up (value fluctuates by battery condition, etc.)
|